Lauritz Knudsen AU Standard RCCB, 4 Pole, Adi 300mA, 100A, 415V | for Household to Industrial applications | Prevents Unauthorized Access | Earth Leakage Fault Indication | with Added Immunity
calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen AU Standard RCCB, 4 Pole, Adi 300mA, 100A, 415V | for Household to Industrial applications | Prevents Unauthorized Access | Earth Leakage Fault Indication | with Added Immunity
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The AU RCCB 100A FP 415V ADI 300mA (AURAD410030) is a high-capacity four pole Residual Current Circuit Breaker engineered to detect earth leakage currents in three phase electrical systems. It is primarily designed for applications where fire protection & equipment safety are critical, rather than direct personal protection.
Integrated with ADI (Advanced Detection Intelligence) technology, this RCCB ensures accurate leakage sensing & dependable tripping performance. With a 100A current rating, it is ideal for high load circuits such as industrial distribution systems, commercial power installations, & main electrical panels.
How the RCCB Works
This RCCB provides dedicated leakage protection through continuous monitoring:
• Monitors current balance across all three phases & neutral
• Detects leakage currents caused by insulation faults or system failures
• Trips automatically when leakage exceeds 300mA threshold
• Disconnects all three phases & neutral simultaneously
This ensures rapid isolation of faults & significantly reduces the risk of electrical fires.
Electrical Configuration
• Rated current: 100A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Technology: ADI (Advanced Detection / Intelligent sensing)
• Sensitivity: 300mA
• Model: AURAD410030
• Function: Earth leakage protection only
• Application: Fire protection & equipment safety
Construction & Design
The RCCB is engineered for heavy-duty applications & long-term reliability:
• Dedicated RCCB functionality for precise leakage detection
• Advanced ADI system for enhanced sensing accuracy
• Modular DIN rail compatible design
• Compact structure optimized for high capacity panels
• High mechanical & electrical endurance
• Designed for stable & consistent tripping performance
Safety & Protection
• Detects earth leakage currents effectively
• 300mA sensitivity suitable for fire protection applications
• Four pole isolation ensures complete disconnection of all phases & neutral
• Helps prevent electrical fires caused by leakage currents
• Enhances protection of electrical systems & equipment
Mounting & Durability
• DIN rail mounting for quick & easy installation
• Suitable for high capacity three phase distribution boards
• Compact modular construction
• Designed for continuous operation under demanding conditions
• Built for long term durability & reliable performance
Application Domains
• Main distribution boards
• Industrial electrical systems
• Commercial power installations
• High load three phase circuits
• Fire protection & safety systems
Key Features
• 100A rated RCCB for high load three phase circuits
• Four pole design for complete phase & neutral isolation
• 300mA sensitivity for fire & equipment protection
• ADI technology for advanced leakage detection
• Model AURAD410030
• Dedicated earth leakage protection device
• DIN rail compatible for easy installation
• Compact & robust construction
Applications
• Industrial panels & machinery
• Commercial electrical systems
• Main distribution boards
• High capacity power circuits
• Fire safety & protection systems
FAQs
1. What is the purpose of this RCCB?
Ans: It detects earth leakage currents & disconnects power to prevent fire hazards & protect electrical equipment.
2. What does 300mA sensitivity indicate?
Ans: It indicates a higher leakage threshold used mainly for fire protection rather than personal safety.
3. Does this RCCB provide overload protection?
Ans: No, it must be used with MCBs for overload & short circuit protection.
4. Why is a four pole RCCB important?
Ans: It disconnects all three phases & neutral, ensuring complete isolation in three phase systems.
5. Where is this 100A FP RCCB used?
Ans: It is used in high load applications such as industrial plants, commercial setups, & main distribution panels.
6. What is ADI technology?
Ans: ADI improves leakage detection accuracy & ensures reliable & consistent tripping performance.
7. Where should this RCCB be installed?
Ans: It should be installed in three phase distribution boards for effective earth leakage protection.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (rigid) / 35 Sq. mm (flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 300mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The AU RCCB 100A FP 415V ADI 300mA (AURAD410030) is a high-capacity four pole Residual Current Circuit Breaker engineered to detect earth leakage currents in three phase electrical systems. It is primarily designed for applications where fire protection & equipment safety are critical, rather than direct personal protection.
Integrated with ADI (Advanced Detection Intelligence) technology, this RCCB ensures accurate leakage sensing & dependable tripping performance. With a 100A current rating, it is ideal for high load circuits such as industrial distribution systems, commercial power installations, & main electrical panels.
How the RCCB Works
This RCCB provides dedicated leakage protection through continuous monitoring:
• Monitors current balance across all three phases & neutral
• Detects leakage currents caused by insulation faults or system failures
• Trips automatically when leakage exceeds 300mA threshold
• Disconnects all three phases & neutral simultaneously
This ensures rapid isolation of faults & significantly reduces the risk of electrical fires.
Electrical Configuration
• Rated current: 100A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Technology: ADI (Advanced Detection / Intelligent sensing)
• Sensitivity: 300mA
• Model: AURAD410030
• Function: Earth leakage protection only
• Application: Fire protection & equipment safety
Construction & Design
The RCCB is engineered for heavy-duty applications & long-term reliability:
• Dedicated RCCB functionality for precise leakage detection
• Advanced ADI system for enhanced sensing accuracy
• Modular DIN rail compatible design
• Compact structure optimized for high capacity panels
• High mechanical & electrical endurance
• Designed for stable & consistent tripping performance
Safety & Protection
• Detects earth leakage currents effectively
• 300mA sensitivity suitable for fire protection applications
• Four pole isolation ensures complete disconnection of all phases & neutral
• Helps prevent electrical fires caused by leakage currents
• Enhances protection of electrical systems & equipment
Mounting & Durability
• DIN rail mounting for quick & easy installation
• Suitable for high capacity three phase distribution boards
• Compact modular construction
• Designed for continuous operation under demanding conditions
• Built for long term durability & reliable performance
Application Domains
• Main distribution boards
• Industrial electrical systems
• Commercial power installations
• High load three phase circuits
• Fire protection & safety systems
Key Features
• 100A rated RCCB for high load three phase circuits
• Four pole design for complete phase & neutral isolation
• 300mA sensitivity for fire & equipment protection
• ADI technology for advanced leakage detection
• Model AURAD410030
• Dedicated earth leakage protection device
• DIN rail compatible for easy installation
• Compact & robust construction
Applications
• Industrial panels & machinery
• Commercial electrical systems
• Main distribution boards
• High capacity power circuits
• Fire safety & protection systems
FAQs
1. What is the purpose of this RCCB?
Ans: It detects earth leakage currents & disconnects power to prevent fire hazards & protect electrical equipment.
2. What does 300mA sensitivity indicate?
Ans: It indicates a higher leakage threshold used mainly for fire protection rather than personal safety.
3. Does this RCCB provide overload protection?
Ans: No, it must be used with MCBs for overload & short circuit protection.
4. Why is a four pole RCCB important?
Ans: It disconnects all three phases & neutral, ensuring complete isolation in three phase systems.
5. Where is this 100A FP RCCB used?
Ans: It is used in high load applications such as industrial plants, commercial setups, & main distribution panels.
6. What is ADI technology?
Ans: ADI improves leakage detection accuracy & ensures reliable & consistent tripping performance.
7. Where should this RCCB be installed?
Ans: It should be installed in three phase distribution boards for effective earth leakage protection.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (rigid) / 35 Sq. mm (flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 300mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 70 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.