Lauritz Knudsen AU Standard RCCB, 2 Pole, Adi 30mA, 63A, 240V | for Household to Industrial applications | Prevents Unauthorized Access | Earth Leakage Fault Indication | with Added Immunity
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen AU Standard RCCB, 2 Pole, Adi 30mA, 63A, 240V | for Household to Industrial applications | Prevents Unauthorized Access | Earth Leakage Fault Indication | with Added Immunity
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The AU RCCB 63A DP 240V ADI 30mA is a high-capacity Residual Current Circuit Breaker designed to provide efficient protection against earth leakage faults. It helps prevent electric shock & fire hazards by disconnecting the circuit when leakage currents are detected.
Equipped with ADI (Advanced Detection Intelligence) technology, this RCCB ensures accurate & fast detection of leakage currents. With a 63A current rating, it is suitable for high load circuits typically used in residential main supply lines & commercial installations.
How the RCCB Works
This RCCB provides dedicated leakage protection:
• Continuously monitors current flow between live & neutral
• Detects imbalance caused by leakage current
• Trips instantly when leakage exceeds 30mA threshold
• Disconnects both live & neutral through double pole operation
This ensures rapid fault isolation & enhances overall electrical safety.
Electrical Configuration
• Rated current: 63A
• Poles: Double pole (DP)
• Rated voltage: 240V AC
• Technology: ADI (Advanced Detection / Intelligent sensing)
• Sensitivity: 30mA
• Function: Earth leakage protection only
• Application: Personal safety & leakage fault protection
Construction & Design
The RCCB is engineered for durability & reliable operation:
• Dedicated RCCB functionality for accurate leakage protection
• Advanced ADI sensing improves detection precision
• Compact modular design compatible with DIN rail mounting
• High mechanical & electrical endurance
• Designed for stable & consistent tripping
Safety & Protection
• Protects against electric shock
• Detects earth leakage currents quickly & reliably
• 30mA sensitivity ensures high level of personal safety
• Double pole isolation ensures complete circuit disconnection
• Helps prevent electrical fires caused by leakage faults
Mounting & Durability
• DIN rail mounting for easy installation• Suitable for residential & commercial distribution boards
• Compact modular construction
• Designed for long term use & frequent operation
• Built for reliable performance under high load conditions
Application Domains
• Main distribution boards
• Residential electrical systems
• Commercial installations
• High load single-phase circuits
• Earth leakage protection systems
Key Features
• 63A rated RCCB for high load circuits
• Double pole design for complete circuit isolation
• 30mA sensitivity for personal safety protection
• ADI technology for advanced leakage detection
• Dedicated earth leakage protection device
• DIN rail compatible for easy installation
• Compact & durable design
Applications
• Residential main supply protection
• Commercial electrical systems
• Socket & lighting circuits
• Distribution boards
• Electrical safety installations
FAQs
1. What is the function of this RCCB?
Ans: It provides protection against earth leakage currents to prevent electric shock & fire hazards.
2. What does 30mA sensitivity mean?
Ans: It means the device trips when leakage current exceeds 30mA, ensuring personal safety.
3. Does RCCB provide overload protection?
Ans: No, it should be used with an MCB or fuse for overload & short circuit protection.
4. Why is double pole important?
Ans: It disconnects both live & neutral, ensuring complete circuit isolation during faults.
5. Where is a 63A RCCB used?
Ans: It is used in high load circuits such as main power supply lines in residential & commercial setups.
6. What is ADI technology?
Ans: ADI improves leakage detection accuracy & ensures fast & reliable tripping performance.
7. Where should this RCCB be installed?
Ans: It should be installed in distribution boards to protect circuits from earth leakage faults.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | DP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 63A |
| Rated operational voltage (Ue) | 240V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 30mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The AU RCCB 63A DP 240V ADI 30mA is a high-capacity Residual Current Circuit Breaker designed to provide efficient protection against earth leakage faults. It helps prevent electric shock & fire hazards by disconnecting the circuit when leakage currents are detected.
Equipped with ADI (Advanced Detection Intelligence) technology, this RCCB ensures accurate & fast detection of leakage currents. With a 63A current rating, it is suitable for high load circuits typically used in residential main supply lines & commercial installations.
How the RCCB Works
This RCCB provides dedicated leakage protection:
• Continuously monitors current flow between live & neutral
• Detects imbalance caused by leakage current
• Trips instantly when leakage exceeds 30mA threshold
• Disconnects both live & neutral through double pole operation
This ensures rapid fault isolation & enhances overall electrical safety.
Electrical Configuration
• Rated current: 63A
• Poles: Double pole (DP)
• Rated voltage: 240V AC
• Technology: ADI (Advanced Detection / Intelligent sensing)
• Sensitivity: 30mA
• Function: Earth leakage protection only
• Application: Personal safety & leakage fault protection
Construction & Design
The RCCB is engineered for durability & reliable operation:
• Dedicated RCCB functionality for accurate leakage protection
• Advanced ADI sensing improves detection precision
• Compact modular design compatible with DIN rail mounting
• High mechanical & electrical endurance
• Designed for stable & consistent tripping
Safety & Protection
• Protects against electric shock
• Detects earth leakage currents quickly & reliably
• 30mA sensitivity ensures high level of personal safety
• Double pole isolation ensures complete circuit disconnection
• Helps prevent electrical fires caused by leakage faults
Mounting & Durability
• DIN rail mounting for easy installation• Suitable for residential & commercial distribution boards
• Compact modular construction
• Designed for long term use & frequent operation
• Built for reliable performance under high load conditions
Application Domains
• Main distribution boards
• Residential electrical systems
• Commercial installations
• High load single-phase circuits
• Earth leakage protection systems
Key Features
• 63A rated RCCB for high load circuits
• Double pole design for complete circuit isolation
• 30mA sensitivity for personal safety protection
• ADI technology for advanced leakage detection
• Dedicated earth leakage protection device
• DIN rail compatible for easy installation
• Compact & durable design
Applications
• Residential main supply protection
• Commercial electrical systems
• Socket & lighting circuits
• Distribution boards
• Electrical safety installations
FAQs
1. What is the function of this RCCB?
Ans: It provides protection against earth leakage currents to prevent electric shock & fire hazards.
2. What does 30mA sensitivity mean?
Ans: It means the device trips when leakage current exceeds 30mA, ensuring personal safety.
3. Does RCCB provide overload protection?
Ans: No, it should be used with an MCB or fuse for overload & short circuit protection.
4. Why is double pole important?
Ans: It disconnects both live & neutral, ensuring complete circuit isolation during faults.
5. Where is a 63A RCCB used?
Ans: It is used in high load circuits such as main power supply lines in residential & commercial setups.
6. What is ADI technology?
Ans: ADI improves leakage detection accuracy & ensures fast & reliable tripping performance.
7. Where should this RCCB be installed?
Ans: It should be installed in distribution boards to protect circuits from earth leakage faults.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | DP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1kA |
| Rated Impulse Voltage | 6kV |
| Rated Conditional SC Current | 10kA |
| Current Rating | 63A |
| Rated operational voltage (Ue) | 240V |
| Conformance to Standards | IEC 61008-1 |
| Sensitivity | 30mA |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.