Lauritz Knudsen Manual Changeover Switch, C-Line, 630A, 415V AC | Frame 4 | 4 Pole | SS Enclosure Extended Handle| Load‑Handling Capability
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen Manual Changeover Switch, C-Line, 630A, 415V AC | Frame 4 | 4 Pole | SS Enclosure Extended Handle| Load‑Handling Capability
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Lauritz Knudsen C-Line Manual Changeover Switch FR4 630A 4P 415V AC with SS (stainless steel) enclosure is a heavy-duty, ultra high-capacity switching solution engineered for safe & efficient transfer of electrical load between two power sources such as mains supply & generator backup.
This model features a strong stainless steel enclosure that provides excellent protection against dust, moisture, corrosion, & harsh environmental conditions. The extended handle enables convenient & safe external operation without opening the enclosure, ensuring enhanced operator safety & ease of use.
As part of the FR4 series, this switch is designed for demanding industrial environments & high-load applications. Its 4-pole (4P) configuration ensures complete isolation of all conductors including neutral, delivering superior safety, reliability, & uninterrupted operation.
Purpose & Function
This enclosed manual changeover switch ensures secure & reliable power management:
• Transfers electrical load between mains & generator supply
• Provides complete circuit isolation during switching
• Enables safe external operation using an extended handle
• Ensures uninterrupted power during supply transitions
• Enhances safety through fully enclosed design
Electrical Configuration
• Type: Manual Changeover Switch
• Series: C-Line FR4
• Current rating: 630A
• Rated voltage: 415V AC
• Poles: 4 Pole (4P)
• Enclosure: Stainless Steel (SS)
• Operation: Extended handle
• Function: Power source switching & isolation
Construction & Design
The switch is engineered for durability & extreme load conditions:
• Stainless steel enclosure for corrosion resistance & long life
• Heavy-duty industrial-grade construction
• Extended handle for easy & safe external operation
• High-strength design for ultra high current handling
• High-quality contact system for consistent & reliable switching
Safety & Protection
• SS enclosure protects against environmental factors & accidental contact
• 4-pole configuration ensures full circuit isolation including neutral
• Reduces risk of electrical faults & hazards
• Improves operator safety during operation
• Ensures dependable performance in harsh & industrial environments
Mounting & Installation
• Suitable for wall or panel mounting
• Enclosed design allows installation in exposed & semi-outdoor areas
• Extended handle eliminates the need to open enclosure during operation
• Compatible with standard industrial electrical systems
• Supports neat, secure, & organized wiring
Application Domains
• Heavy industrial power distribution systems
• Large commercial & infrastructure projects
• Generator backup systems
• Outdoor & semi-outdoor installations
• Electrical control & distribution panels
• Manufacturing & processing plants
Key Features
• 630A current rating for ultra high-capacity applications
• 415V AC operation for three phase systems
• 4-pole configuration for complete electrical isolation
• Stainless steel enclosure for superior protection
• Extended handle for safe & convenient external operation
• Durable & heavy-duty industrial-grade design
Applications
• Generator changeover panels
• Industrial distribution boards
• Commercial & infrastructure electrical systems
• Outdoor electrical installations
• Backup & emergency power systems
FAQs
1. What is the purpose of this changeover switch?
Ans: It safely transfers electrical load between two power sources such as mains & generator.
2. What does 4P mean?
Ans: 4P (four-pole) means all conductors including neutral are fully isolated for maximum safety.
3. What is the benefit of a stainless steel enclosure?
Ans: It provides protection against dust, moisture, corrosion, & physical damage, ensuring long-term durability.
4. What is the advantage of an extended handle?
Ans: It allows operation of the switch from outside the enclosure without opening it, improving safety & convenience.
5. Can this switch be used outdoors?
Ans: Yes, the SS enclosed design makes it suitable for outdoor & semi-outdoor applications.
6. Is this suitable for heavy industrial use?
Ans: Yes, it is designed for ultra high-load industrial & commercial applications.
7. Why is complete isolation important?
Ans: Complete isolation ensures safe maintenance & switching by fully disconnecting the electrical circuit.
Overview
| Rated Operational Current (A) | 630 |
|---|---|
| Conformance to Standards | IS/IEC 60947-3, EN 60947-3 |
| Utilization Category | AC-23A |
| Rated operational voltage (Ue) | 415V |
| Operating Frequency(Hz) | 50/60 |
| Mechanical Life (No. of operating cycles) | 10000 |
| Rated Insulation Voltage Ui (V) | 1000 |
| Short Time Withstand for 1sec (kA) | 26 |
| Rated Operational Power (kW) | 315 |
| Rated Breaking Capacity@AC-23A (A) | 5040 |
| Rated Making Capacity@AC-23A (A) | 6300 |
| Version | Manual, SS enclosure |
| No. of Poles | 4P |
| Electrical life (Operating Cylces) | 2000 |
| Mechanical Life (Operating Cycles) | 10000 |
| Maximum Al termination (sq.mm) | 2*300 |
| Standard Accessories | Terminal Shroud,Phase Barriers,Source Separator, Extended handle with shaft |
| Pollution Degree | 3 |
| Rated impulse withstand voltage (Uimp) | 12 |
| Discount Percentage | Between 0-10 % |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Lauritz Knudsen C-Line Manual Changeover Switch FR4 630A 4P 415V AC with SS (stainless steel) enclosure is a heavy-duty, ultra high-capacity switching solution engineered for safe & efficient transfer of electrical load between two power sources such as mains supply & generator backup.
This model features a strong stainless steel enclosure that provides excellent protection against dust, moisture, corrosion, & harsh environmental conditions. The extended handle enables convenient & safe external operation without opening the enclosure, ensuring enhanced operator safety & ease of use.
As part of the FR4 series, this switch is designed for demanding industrial environments & high-load applications. Its 4-pole (4P) configuration ensures complete isolation of all conductors including neutral, delivering superior safety, reliability, & uninterrupted operation.
Purpose & Function
This enclosed manual changeover switch ensures secure & reliable power management:
• Transfers electrical load between mains & generator supply
• Provides complete circuit isolation during switching
• Enables safe external operation using an extended handle
• Ensures uninterrupted power during supply transitions
• Enhances safety through fully enclosed design
Electrical Configuration
• Type: Manual Changeover Switch
• Series: C-Line FR4
• Current rating: 630A
• Rated voltage: 415V AC
• Poles: 4 Pole (4P)
• Enclosure: Stainless Steel (SS)
• Operation: Extended handle
• Function: Power source switching & isolation
Construction & Design
The switch is engineered for durability & extreme load conditions:
• Stainless steel enclosure for corrosion resistance & long life
• Heavy-duty industrial-grade construction
• Extended handle for easy & safe external operation
• High-strength design for ultra high current handling
• High-quality contact system for consistent & reliable switching
Safety & Protection
• SS enclosure protects against environmental factors & accidental contact
• 4-pole configuration ensures full circuit isolation including neutral
• Reduces risk of electrical faults & hazards
• Improves operator safety during operation
• Ensures dependable performance in harsh & industrial environments
Mounting & Installation
• Suitable for wall or panel mounting
• Enclosed design allows installation in exposed & semi-outdoor areas
• Extended handle eliminates the need to open enclosure during operation
• Compatible with standard industrial electrical systems
• Supports neat, secure, & organized wiring
Application Domains
• Heavy industrial power distribution systems
• Large commercial & infrastructure projects
• Generator backup systems
• Outdoor & semi-outdoor installations
• Electrical control & distribution panels
• Manufacturing & processing plants
Key Features
• 630A current rating for ultra high-capacity applications
• 415V AC operation for three phase systems
• 4-pole configuration for complete electrical isolation
• Stainless steel enclosure for superior protection
• Extended handle for safe & convenient external operation
• Durable & heavy-duty industrial-grade design
Applications
• Generator changeover panels
• Industrial distribution boards
• Commercial & infrastructure electrical systems
• Outdoor electrical installations
• Backup & emergency power systems
FAQs
1. What is the purpose of this changeover switch?
Ans: It safely transfers electrical load between two power sources such as mains & generator.
2. What does 4P mean?
Ans: 4P (four-pole) means all conductors including neutral are fully isolated for maximum safety.
3. What is the benefit of a stainless steel enclosure?
Ans: It provides protection against dust, moisture, corrosion, & physical damage, ensuring long-term durability.
4. What is the advantage of an extended handle?
Ans: It allows operation of the switch from outside the enclosure without opening it, improving safety & convenience.
5. Can this switch be used outdoors?
Ans: Yes, the SS enclosed design makes it suitable for outdoor & semi-outdoor applications.
6. Is this suitable for heavy industrial use?
Ans: Yes, it is designed for ultra high-load industrial & commercial applications.
7. Why is complete isolation important?
Ans: Complete isolation ensures safe maintenance & switching by fully disconnecting the electrical circuit.
Overview
| Rated Operational Current (A) | 630 |
|---|---|
| Conformance to Standards | IS/IEC 60947-3, EN 60947-3 |
| Utilization Category | AC-23A |
| Rated operational voltage (Ue) | 415V |
| Operating Frequency(Hz) | 50/60 |
| Mechanical Life (No. of operating cycles) | 10000 |
| Rated Insulation Voltage Ui (V) | 1000 |
| Short Time Withstand for 1sec (kA) | 26 |
| Rated Operational Power (kW) | 315 |
| Rated Breaking Capacity@AC-23A (A) | 5040 |
| Rated Making Capacity@AC-23A (A) | 6300 |
| Version | Manual, SS enclosure |
| No. of Poles | 4P |
| Electrical life (Operating Cylces) | 2000 |
| Mechanical Life (Operating Cycles) | 10000 |
| Maximum Al termination (sq.mm) | 2*300 |
| Standard Accessories | Terminal Shroud,Phase Barriers,Source Separator, Extended handle with shaft |
| Pollution Degree | 3 |
| Rated impulse withstand voltage (Uimp) | 12 |
| Discount Percentage | Between 0-10 % |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.