calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen DN0SD, MCCB, 4 Pole, 415V AC, 100A | Switch Disconnector | IP40 Protection | MCCBs without protection release
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
The dsineDN series, State-of-the-art design, user-friendly features and a wide spectrum of protection releases form the hallmarks of the range. Also recognised for its ergonomics, aesthetics and compactness, it belongs to a new generation of MCCBs. Specially designed and developed for extreme tropical conditions, it promises reliable performance at high ambient and humid environment. dsineDN Series complies with the latest standards like IS/IEC 60947-2, IEC 60947-2 & EN 60947-2, NABL accreditation and the products conform to international standards, carry CE marking. dsine, unfailingly, caters to the ever-evolving needs of customers, derived after in-depth analysis and customer feedback. Because we understand our customers' requirements and demands, our contemporary range of MCCBs never fall short of ensuring complete customer satisfaction. Moreover, complemented by a host of accessories, the dsine range delivers comprehensive solutions to customer applications ensuring operational safety, reliability and versatility..
Overview
| Rated Operational Current | 100A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | SD |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
The dsineDN series, State-of-the-art design, user-friendly features and a wide spectrum of protection releases form the hallmarks of the range. Also recognised for its ergonomics, aesthetics and compactness, it belongs to a new generation of MCCBs. Specially designed and developed for extreme tropical conditions, it promises reliable performance at high ambient and humid environment. dsineDN Series complies with the latest standards like IS/IEC 60947-2, IEC 60947-2 & EN 60947-2, NABL accreditation and the products conform to international standards, carry CE marking. dsine, unfailingly, caters to the ever-evolving needs of customers, derived after in-depth analysis and customer feedback. Because we understand our customers' requirements and demands, our contemporary range of MCCBs never fall short of ensuring complete customer satisfaction. Moreover, complemented by a host of accessories, the dsine range delivers comprehensive solutions to customer applications ensuring operational safety, reliability and versatility..
Overview
| Rated Operational Current | 100A |
|---|---|
| Mechanical Life (No. of operating cycles) | 40000 |
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | SD |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.