Lauritz Knudsen DN1M, MCCB, 3 Pole, 415V AC, 50kA Breaking Capacity, 160A | Motor back-up Protection | IP40 Protection
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
Lauritz Knudsen CM90345OOMO dsineDN Series
The dsineDN Series
The dsineDN series is characterized by its state-of-the-art design, user-friendly features, and a wide spectrum of protection, making it the hallmark of the range. Recognized for its ergonomics, aesthetics, and compactness, it belongs to a new generation of MCCBs.
Specially designed and developed for extreme tropical conditions, it promises reliable performance in high ambient and humid environments. The dsineDN Series complies with the latest standards such as IS/IEC 60947-2, IEC 60947-2, and EN 60947-2. It also holds NABL accreditation, and the products conform to international standards with CE marking.
dsine, unfailingly, caters to the ever-evolving needs of customers, derived after in-depth analysis and customer feedback. Understanding our customers' requirements and demands, our contemporary range of MCCBs never falls short of ensuring complete customer satisfaction. Moreover, complemented by a host of accessories, the dsine range delivers comprehensive solutions to customer applications, ensuring operational safety, reliability, and versatility.
Overview
| Rated Operational Current | 160 |
|---|---|
| Mechanical Life (No. of operating cycles) | 25000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | M |
| Rated Short Circuit Breaking capacity Icu(kA) | DN1M MCCB 160 3P 415V AC 50kA M 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 10000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 105 |
| Height(mm) | 165 |
| Depth(mm) | 60 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
Lauritz Knudsen CM90345OOMO dsineDN Series
The dsineDN Series
The dsineDN series is characterized by its state-of-the-art design, user-friendly features, and a wide spectrum of protection, making it the hallmark of the range. Recognized for its ergonomics, aesthetics, and compactness, it belongs to a new generation of MCCBs.
Specially designed and developed for extreme tropical conditions, it promises reliable performance in high ambient and humid environments. The dsineDN Series complies with the latest standards such as IS/IEC 60947-2, IEC 60947-2, and EN 60947-2. It also holds NABL accreditation, and the products conform to international standards with CE marking.
dsine, unfailingly, caters to the ever-evolving needs of customers, derived after in-depth analysis and customer feedback. Understanding our customers' requirements and demands, our contemporary range of MCCBs never falls short of ensuring complete customer satisfaction. Moreover, complemented by a host of accessories, the dsine range delivers comprehensive solutions to customer applications, ensuring operational safety, reliability, and versatility.
Overview
| Rated Operational Current | 160 |
|---|---|
| Mechanical Life (No. of operating cycles) | 25000 |
| No. of Poles | 3P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Conformance to Standards | IEC 60947-1, EN 60947-1, IS/IEC 60947-1 IEC 60947-2, EN 60947-2, IS/IEC 60947-2 IEC 60947-3, EN 60947-3, IS/IEC 60947-3 IEC 60947-4, EN 60947-4, IS/IEC 60947-4 |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | M |
| Rated Short Circuit Breaking capacity Icu(kA) | DN1M MCCB 160 3P 415V AC 50kA M 50/60 Hz |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50kA |
| Ambient temperature | -5°C to 55°C |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 10000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 105 |
| Height(mm) | 165 |
| Depth(mm) | 60 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.