Lauritz Knudsen DU100H, MCCB, 4 Pole, 415V AC, 30kA Breaking Capacity, 32A | Thermal-Magnetic Release| 50/60 Hz | Compact Size
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen DU100H, MCCB, 4 Pole, 415V AC, 30kA Breaking Capacity, 32A | Thermal-Magnetic Release| 50/60 Hz | Compact Size
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Lauritz Knudsen CM97933OOE2 from the DU100H series is a high-performance 4 Pole Moulded Case Circuit Breaker (MCCB) designed to provide reliable circuit protection & complete electrical isolation for industrial, commercial, & infrastructure power distribution systems. Rated at 32A & 415V AC, this MCCB delivers dependable protection against overload & short-circuit faults while ensuring enhanced operational safety & equipment protection.
The breaker incorporates an advanced thermal-magnetic trip mechanism that provides dual-layer protection against electrical abnormalities. The thermal trip element offers time-delayed tripping during overload conditions, protecting cables & connected equipment from sustained overcurrent situations. The magnetic trip element instantly disconnects the circuit during short-circuit faults, minimizing damage to the electrical installation & improving safety.
The 4 Pole configuration includes a dedicated neutral pole, enabling simultaneous isolation of all three phases & the neutral conductor. This feature is particularly important in applications requiring complete circuit disconnection for maintenance, fault isolation, operational safety, & system reliability. Neutral isolation enhances protection in sensitive electrical systems & helps ensure safe working conditions during service activities.
With a high breaking capacity of 30kA, the DU100H MCCB can safely interrupt substantial fault currents before they impact system performance. This high fault-clearing capability helps maintain electrical network stability, protects critical equipment, & minimizes downtime in demanding operating environments.
The MCCB is designed for operation in 50/60 Hz electrical systems, making it suitable for industrial, commercial, infrastructure, & utility installations worldwide. Its compact dimensions allow efficient utilization of panel space while supporting easy installation & maintenance in switchboards & distribution systems.
Manufactured using durable insulating materials & precision-engineered operating components, the breaker delivers long service life, dependable switching performance, & excellent electrical reliability. Its rugged construction ensures consistent protection even under challenging industrial & commercial operating conditions.
The DU100H series is widely utilized in distribution panels, motor control centers, commercial buildings, utility installations, infrastructure projects, & electrical systems where complete phase & neutral isolation, operational safety, & dependable circuit protection are essential.
How the Mechanism Works
The product functions by:
• Continuously monitoring electrical current flow through all connected poles
• Detecting overload conditions using a thermal trip mechanism
• Providing delayed tripping during prolonged overcurrent situations
• Detecting short-circuit faults through a magnetic trip system
• Instantly disconnecting the circuit during fault conditions
• Protecting cables, switchgear, motors, & electrical equipment from damage
• Isolating all phases & the neutral conductor simultaneously
• Enhancing safety during maintenance & servicing procedures
• Improving reliability of power distribution systems
• Supporting stable & secure electrical operation
It serves as a critical protection & isolation device for modern electrical distribution networks.
Electrical Configuration
• Product Type: Moulded Case Circuit Breaker (MCCB)
• Model: CM97933OOE2
• Series: DU100H
• Pole Configuration: 4 Pole
• Rated Current: 32A
• Rated Voltage: 415V AC
• Frequency: 50/60 Hz
• Breaking Capacity: 30kA
• Trip Unit Type: Thermal Magnetic
• Neutral Pole: Included
• Mounting Type: Panel Mounted
• Primary Function: Overload, Short-Circuit Protection & Circuit Isolation
• Application: Electrical Power Distribution Systems
Construction & Design
Designed for durability & dependable operation:
• Compact MCCB construction
• High-strength moulded insulating enclosure
• Precision-engineered operating mechanism
• Thermal-magnetic trip technology
• Four-pole switching architecture
• Integrated neutral pole design
• Heavy-duty contact system
• Advanced arc interruption chamber
• Industrial-grade insulation materials
• Long operational service life
Safety & Protection
• Reliable overload protection
• Instantaneous short-circuit protection
• Complete phase & neutral isolation
• High 30kA fault interruption capability
• Enhanced electrical safety
• Improved protection for connected equipment
• Reduced risk of electrical system damage
• Stable & dependable operation
• Increased power distribution reliability
• Extended equipment lifespan
Mounting & Durability
• Easy installation in electrical panels
• Suitable for distribution boards & switchboards
• Compact footprint for efficient panel integration
• Secure mounting arrangement
• Durable industrial-grade construction
• Designed for continuous-duty operation
• Resistant to electrical & mechanical stress
• Reliable performance in demanding environments
• Long operational lifespan
• Minimal maintenance requirements
Application Domains
• Electrical Distribution Panels
• Industrial Installations
• Commercial Buildings
• Infrastructure Projects
• Utility Power Systems
• Motor Control Centers (MCCs)
• Distribution Boards
• Switchgear Assemblies
• Systems Requiring Neutral Isolation
• Critical Electrical Networks
Key Features
• Rated current of 32A
• 4 Pole configuration for three-phase plus neutral systems
• Rated voltage of 415V AC
• High breaking capacity of 30kA
• Thermal-magnetic trip protection
• Reliable overload & short-circuit protection
• Integrated neutral pole for complete circuit isolation
• Suitable for 50/60 Hz operation
• Compact & rugged design
• Easy panel integration
• Industrial-grade reliability & performance
• Long service life & dependable operation
Applications
• Electrical distribution panels
• Industrial & commercial installations
• Systems requiring neutral isolation
• Motor Control Centers (MCCs)
• Infrastructure & utility systems
• Sensitive electrical equipment protection
• Building power distribution networks
• Switchboards & control panels
• Critical electrical installations
• Electrical safety & isolation systems
FAQs
1. What is the purpose of a 4 Pole MCCB?
Ans: It protects three phases & includes a neutral pole, enabling complete circuit isolation for improved safety & maintenance procedures.
2. What is the current rating of this MCCB?
Ans: The MCCB has a rated current of 32A.
3. What type of protection does it provide?
Ans: It provides thermal protection against overloads & magnetic protection against short-circuit faults.
4. Why is neutral disconnection important?
Ans: Neutral disconnection ensures complete circuit isolation, improving safety during maintenance, servicing, & fault conditions.
5. What is the breaking capacity of this MCCB?
Ans: The breaker has a high breaking capacity of 30kA for safe interruption of significant fault currents.
6. Is it suitable for three-phase systems with neutral connections?
Ans: Yes, the 4 Pole configuration is specifically designed for three-phase systems requiring full neutral isolation & protection.
7. Where is this MCCB commonly installed?
Ans: It is commonly installed in industrial panels, commercial electrical systems, power distribution boards, infrastructure projects, & utility installations.
8. What are the benefits of complete phase & neutral isolation?
Ans: Complete isolation improves personnel safety, supports maintenance activities, reduces fault risks, helps protect sensitive equipment, & enhances overall system reliability.
Overview
| Rated Operational Current (A) | 32A |
|---|---|
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 30kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50% |
| Ambient temperature | -5°C to 55°C |
| Conformance to Standards | IS 60947-2, IEC 60947-2 & EN 60947-2 |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| Mechanical Life (Operating Cycles) | 40000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
| Discount Percentage | Between 0-10 % |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Lauritz Knudsen CM97933OOE2 from the DU100H series is a high-performance 4 Pole Moulded Case Circuit Breaker (MCCB) designed to provide reliable circuit protection & complete electrical isolation for industrial, commercial, & infrastructure power distribution systems. Rated at 32A & 415V AC, this MCCB delivers dependable protection against overload & short-circuit faults while ensuring enhanced operational safety & equipment protection.
The breaker incorporates an advanced thermal-magnetic trip mechanism that provides dual-layer protection against electrical abnormalities. The thermal trip element offers time-delayed tripping during overload conditions, protecting cables & connected equipment from sustained overcurrent situations. The magnetic trip element instantly disconnects the circuit during short-circuit faults, minimizing damage to the electrical installation & improving safety.
The 4 Pole configuration includes a dedicated neutral pole, enabling simultaneous isolation of all three phases & the neutral conductor. This feature is particularly important in applications requiring complete circuit disconnection for maintenance, fault isolation, operational safety, & system reliability. Neutral isolation enhances protection in sensitive electrical systems & helps ensure safe working conditions during service activities.
With a high breaking capacity of 30kA, the DU100H MCCB can safely interrupt substantial fault currents before they impact system performance. This high fault-clearing capability helps maintain electrical network stability, protects critical equipment, & minimizes downtime in demanding operating environments.
The MCCB is designed for operation in 50/60 Hz electrical systems, making it suitable for industrial, commercial, infrastructure, & utility installations worldwide. Its compact dimensions allow efficient utilization of panel space while supporting easy installation & maintenance in switchboards & distribution systems.
Manufactured using durable insulating materials & precision-engineered operating components, the breaker delivers long service life, dependable switching performance, & excellent electrical reliability. Its rugged construction ensures consistent protection even under challenging industrial & commercial operating conditions.
The DU100H series is widely utilized in distribution panels, motor control centers, commercial buildings, utility installations, infrastructure projects, & electrical systems where complete phase & neutral isolation, operational safety, & dependable circuit protection are essential.
How the Mechanism Works
The product functions by:
• Continuously monitoring electrical current flow through all connected poles
• Detecting overload conditions using a thermal trip mechanism
• Providing delayed tripping during prolonged overcurrent situations
• Detecting short-circuit faults through a magnetic trip system
• Instantly disconnecting the circuit during fault conditions
• Protecting cables, switchgear, motors, & electrical equipment from damage
• Isolating all phases & the neutral conductor simultaneously
• Enhancing safety during maintenance & servicing procedures
• Improving reliability of power distribution systems
• Supporting stable & secure electrical operation
It serves as a critical protection & isolation device for modern electrical distribution networks.
Electrical Configuration
• Product Type: Moulded Case Circuit Breaker (MCCB)
• Model: CM97933OOE2
• Series: DU100H
• Pole Configuration: 4 Pole
• Rated Current: 32A
• Rated Voltage: 415V AC
• Frequency: 50/60 Hz
• Breaking Capacity: 30kA
• Trip Unit Type: Thermal Magnetic
• Neutral Pole: Included
• Mounting Type: Panel Mounted
• Primary Function: Overload, Short-Circuit Protection & Circuit Isolation
• Application: Electrical Power Distribution Systems
Construction & Design
Designed for durability & dependable operation:
• Compact MCCB construction
• High-strength moulded insulating enclosure
• Precision-engineered operating mechanism
• Thermal-magnetic trip technology
• Four-pole switching architecture
• Integrated neutral pole design
• Heavy-duty contact system
• Advanced arc interruption chamber
• Industrial-grade insulation materials
• Long operational service life
Safety & Protection
• Reliable overload protection
• Instantaneous short-circuit protection
• Complete phase & neutral isolation
• High 30kA fault interruption capability
• Enhanced electrical safety
• Improved protection for connected equipment
• Reduced risk of electrical system damage
• Stable & dependable operation
• Increased power distribution reliability
• Extended equipment lifespan
Mounting & Durability
• Easy installation in electrical panels
• Suitable for distribution boards & switchboards
• Compact footprint for efficient panel integration
• Secure mounting arrangement
• Durable industrial-grade construction
• Designed for continuous-duty operation
• Resistant to electrical & mechanical stress
• Reliable performance in demanding environments
• Long operational lifespan
• Minimal maintenance requirements
Application Domains
• Electrical Distribution Panels
• Industrial Installations
• Commercial Buildings
• Infrastructure Projects
• Utility Power Systems
• Motor Control Centers (MCCs)
• Distribution Boards
• Switchgear Assemblies
• Systems Requiring Neutral Isolation
• Critical Electrical Networks
Key Features
• Rated current of 32A
• 4 Pole configuration for three-phase plus neutral systems
• Rated voltage of 415V AC
• High breaking capacity of 30kA
• Thermal-magnetic trip protection
• Reliable overload & short-circuit protection
• Integrated neutral pole for complete circuit isolation
• Suitable for 50/60 Hz operation
• Compact & rugged design
• Easy panel integration
• Industrial-grade reliability & performance
• Long service life & dependable operation
Applications
• Electrical distribution panels
• Industrial & commercial installations
• Systems requiring neutral isolation
• Motor Control Centers (MCCs)
• Infrastructure & utility systems
• Sensitive electrical equipment protection
• Building power distribution networks
• Switchboards & control panels
• Critical electrical installations
• Electrical safety & isolation systems
FAQs
1. What is the purpose of a 4 Pole MCCB?
Ans: It protects three phases & includes a neutral pole, enabling complete circuit isolation for improved safety & maintenance procedures.
2. What is the current rating of this MCCB?
Ans: The MCCB has a rated current of 32A.
3. What type of protection does it provide?
Ans: It provides thermal protection against overloads & magnetic protection against short-circuit faults.
4. Why is neutral disconnection important?
Ans: Neutral disconnection ensures complete circuit isolation, improving safety during maintenance, servicing, & fault conditions.
5. What is the breaking capacity of this MCCB?
Ans: The breaker has a high breaking capacity of 30kA for safe interruption of significant fault currents.
6. Is it suitable for three-phase systems with neutral connections?
Ans: Yes, the 4 Pole configuration is specifically designed for three-phase systems requiring full neutral isolation & protection.
7. Where is this MCCB commonly installed?
Ans: It is commonly installed in industrial panels, commercial electrical systems, power distribution boards, infrastructure projects, & utility installations.
8. What are the benefits of complete phase & neutral isolation?
Ans: Complete isolation improves personnel safety, supports maintenance activities, reduces fault risks, helps protect sensitive equipment, & enhances overall system reliability.
Overview
| Rated Operational Current (A) | 32A |
|---|---|
| No. of Poles | 4P |
| Rated Operational voltage (Ue) | 415V AC |
| Rated Insulation Voltage Ui (V) | 800 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Operational Frequency (Hz) | 50/60 Hz |
| Release Type | Thermal Magnetic |
| Rated Short Circuit Breaking capacity Icu(kA) | 30kA |
| Rated Sevice circuit breaking capacity (Ics as % of Icu) @415VAC | 50% |
| Ambient temperature | -5°C to 55°C |
| Conformance to Standards | IS 60947-2, IEC 60947-2 & EN 60947-2 |
| Suitable for isolation | Yes |
| Load-line bias | No |
| Electrical Life (Operating Cycles) | 8000 |
| Mechanical Life (Operating Cycles) | 40000 |
| IP Protection | IP40 |
| Pollution Degree | III |
| Width(mm) | 100 |
| Height(mm) | 130 |
| Depth(mm) | 60 |
| Discount Percentage | Between 0-10 % |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.