Lauritz Knudsen EXORA, Distribution Board (DB) Phase Selector, Double Door, IP43, 63A, 6 Way
calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen EXORA, Distribution Board (DB) Phase Selector, Double Door, IP43, 63A, 6 Way
- Description
- Specifications
- Warranty
- Reviews
Description
About the Product
The Exora 63A Phase Selector 6 Way Double Door IP43 distribution board is designed for controlled phase selection and distribution of electrical power across multiple circuits. It supports up to 6 outgoing ways and is suitable for applications where load balancing across available phases is required.
It operates with a phase selector mechanism rated up to 63A, enabling manual selection between phases for optimized power utilization. The double door enclosure combined with IP43 protection ensures enhanced safety and durability for semi protected environments.
How the Distribution Board Works
This phase selector distribution board operates using a controlled switching system:
- The phase selector allows selection between available supply phases
- Electrical input is routed through the selector mechanism
- The selected phase is distributed to outgoing circuits
- Enables manual balancing of load across different phases
This mechanism ensures flexibility and continuity of supply in multi phase systems.
Electrical Configuration
- System type: Phase selector distribution board
- Way / capacity: 6 way
- Incomer: Phase selector switch up to 63A
- Outgoing configuration: 6 modular ways
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal design:
- Integrated phase selector switching mechanism
- Modular DIN rail arrangement for outgoing devices
- Neutral and earth bar provisions
- Adequate space for wiring and cable management
- Circuit identification and labeling provision
The enclosure is designed for efficient installation and organized circuit routing.
Safety and Protection
- Phase selector enables controlled switching between supply phases
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with internal components
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact enclosure suitable for medium capacity installations
- Robust metal construction with protective coating
- Suitable for commercial and industrial environments
- Built for reliable long term operation
Application Domains
- Phase balancing in commercial installations
- Load selection in multi phase systems
- Control panels and switchboards
- Industrial distribution systems
- Backup phase selection systems
Key Features
- 63A phase selector for controlled phase switching
- 6 way configuration for multiple outgoing circuits
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible for modular device integration
- Structured internal layout for organized wiring
- Compact and durable enclosure design
Applications
- Commercial buildings
- Electrical control panels
- Industrial panels
- Phase balancing systems
- Multi phase load management
FAQs
1. What is the function of a phase selector in this distribution board?
Ans: The phase selector allows manual selection between available phases to distribute power and balance electrical load.
2. What is the rated current of this phase selector DB?
Ans: The phase selector is rated up to 63A.
3. What does 6 way mean?
Ans: It indicates that the distribution board supports up to six outgoing circuits.
4. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
5. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
6. Is this distribution board suitable for industrial use?
Ans: Yes, it can be used in industrial and commercial environments for phase selection and distribution.
7. Can this be used for automatic phase selection?
Ans: No, this is a manual phase selector and requires manual switching between phases.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 8 |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 4+4+4 |
| Height(mm) | 556 |
| Breadth(mm) | 480 |
| Depth(mm) | 155 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Exora 63A Phase Selector 6 Way Double Door IP43 distribution board is designed for controlled phase selection and distribution of electrical power across multiple circuits. It supports up to 6 outgoing ways and is suitable for applications where load balancing across available phases is required.
It operates with a phase selector mechanism rated up to 63A, enabling manual selection between phases for optimized power utilization. The double door enclosure combined with IP43 protection ensures enhanced safety and durability for semi protected environments.
How the Distribution Board Works
This phase selector distribution board operates using a controlled switching system:
- The phase selector allows selection between available supply phases
- Electrical input is routed through the selector mechanism
- The selected phase is distributed to outgoing circuits
- Enables manual balancing of load across different phases
This mechanism ensures flexibility and continuity of supply in multi phase systems.
Electrical Configuration
- System type: Phase selector distribution board
- Way / capacity: 6 way
- Incomer: Phase selector switch up to 63A
- Outgoing configuration: 6 modular ways
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal design:
- Integrated phase selector switching mechanism
- Modular DIN rail arrangement for outgoing devices
- Neutral and earth bar provisions
- Adequate space for wiring and cable management
- Circuit identification and labeling provision
The enclosure is designed for efficient installation and organized circuit routing.
Safety and Protection
- Phase selector enables controlled switching between supply phases
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with internal components
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact enclosure suitable for medium capacity installations
- Robust metal construction with protective coating
- Suitable for commercial and industrial environments
- Built for reliable long term operation
Application Domains
- Phase balancing in commercial installations
- Load selection in multi phase systems
- Control panels and switchboards
- Industrial distribution systems
- Backup phase selection systems
Key Features
- 63A phase selector for controlled phase switching
- 6 way configuration for multiple outgoing circuits
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible for modular device integration
- Structured internal layout for organized wiring
- Compact and durable enclosure design
Applications
- Commercial buildings
- Electrical control panels
- Industrial panels
- Phase balancing systems
- Multi phase load management
FAQs
1. What is the function of a phase selector in this distribution board?
Ans: The phase selector allows manual selection between available phases to distribute power and balance electrical load.
2. What is the rated current of this phase selector DB?
Ans: The phase selector is rated up to 63A.
3. What does 6 way mean?
Ans: It indicates that the distribution board supports up to six outgoing circuits.
4. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
5. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
6. Is this distribution board suitable for industrial use?
Ans: Yes, it can be used in industrial and commercial environments for phase selection and distribution.
7. Can this be used for automatic phase selection?
Ans: No, this is a manual phase selector and requires manual switching between phases.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 8 |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 4+4+4 |
| Height(mm) | 556 |
| Breadth(mm) | 480 |
| Depth(mm) | 155 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.