About the Product
Exora DB VTPN 6 Way Double Door IP43 Modular with 125A MCCB is a vertical three phase and neutral distribution board enclosure designed to accommodate up to 6 outgoing ways for modular protection devices such as MCBs, RCCBs, and isolators. It features an integrated 125A MCCB incomer that provides high-level protection against overloads and short circuit faults. The double door construction and IP43 protection rating make it suitable for environments requiring enhanced safety and resistance to dust and water splashes.
How the Mechanism Works
This VTPN distribution board operates as a structured three-phase power distribution system:
- The 125A MCCB incomer acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases along with neutral
- Outgoing circuits are managed using modular protective devices
- Ensures safe, organized, and balanced load distribution across all phases
The MCCB provides centralized system protection, ensuring reliable operation.
Construction and Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 6 way
- Incomer: 125A MCCB
- Door type: Double door
- Protection rating: IP43
- Mounting type: Surface or wall mount
Standard internal configuration includes:
- Insulated busbar system for three-phase distribution
- Neutral and earth bars
- DIN rail mounting system for modular devices
- Adequate internal wiring and cable management space
- Circuit identification and labeling provision
Safety & Protection
- 125A MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door design enhances safety and controlled access
- Prevents accidental contact with live electrical components
- Organized internal layout reduces wiring faults and improves reliability
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Durable metal construction with protective finish
- Suitable for commercial and industrial environments
- Built for long-term durability and consistent performance
Application Domains
- Commercial electrical distribution systems
- Industrial installations and facilities
- Three-phase residential setups
- Control and distribution panels
- Protected sub-distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 6 way circuit capacity
- Integrated 125A MCCB incomer for advanced protection
- Double door enclosure for enhanced safety
- IP43 protection against dust and water splashes
- Compact vertical design
- Supports MCB, RCCB, and isolator installation
- DIN rail compatible system
- Structured multi-phase distribution
- Easy installation and maintenance
- Durable construction
Applications
- Commercial buildings
- Industrial environments
- Electrical control panels
- Machinery power distribution
- Three-phase load management systems
FAQs
- 1. What is the role of the 125A MCCB in this DB?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions.
- 2. What is a VTPN distribution board?
Ans: It is a vertical distribution board designed for three-phase and neutral power distribution.
- 3. What does 6 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
- 4. What is the advantage of a double door enclosure?
Ans: It enhances safety by providing controlled access and additional protection for internal components.
- 5. What does IP43 protection mean?
Ans: It provides protection against dust and water splashes in semi-protected environments.
- 6. Can it be used outdoors?
Ans: It is suitable for covered or semi-protected installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 125A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 8+8+8 |
| Height(mm) | 588 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
Exora DB VTPN 6 Way Double Door IP43 Modular with 125A MCCB is a vertical three phase and neutral distribution board enclosure designed to accommodate up to 6 outgoing ways for modular protection devices such as MCBs, RCCBs, and isolators. It features an integrated 125A MCCB incomer that provides high-level protection against overloads and short circuit faults. The double door construction and IP43 protection rating make it suitable for environments requiring enhanced safety and resistance to dust and water splashes.
How the Mechanism Works
This VTPN distribution board operates as a structured three-phase power distribution system:
- The 125A MCCB incomer acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases along with neutral
- Outgoing circuits are managed using modular protective devices
- Ensures safe, organized, and balanced load distribution across all phases
The MCCB provides centralized system protection, ensuring reliable operation.
Construction and Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 6 way
- Incomer: 125A MCCB
- Door type: Double door
- Protection rating: IP43
- Mounting type: Surface or wall mount
Standard internal configuration includes:
- Insulated busbar system for three-phase distribution
- Neutral and earth bars
- DIN rail mounting system for modular devices
- Adequate internal wiring and cable management space
- Circuit identification and labeling provision
Safety & Protection
- 125A MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door design enhances safety and controlled access
- Prevents accidental contact with live electrical components
- Organized internal layout reduces wiring faults and improves reliability
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Durable metal construction with protective finish
- Suitable for commercial and industrial environments
- Built for long-term durability and consistent performance
Application Domains
- Commercial electrical distribution systems
- Industrial installations and facilities
- Three-phase residential setups
- Control and distribution panels
- Protected sub-distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 6 way circuit capacity
- Integrated 125A MCCB incomer for advanced protection
- Double door enclosure for enhanced safety
- IP43 protection against dust and water splashes
- Compact vertical design
- Supports MCB, RCCB, and isolator installation
- DIN rail compatible system
- Structured multi-phase distribution
- Easy installation and maintenance
- Durable construction
Applications
- Commercial buildings
- Industrial environments
- Electrical control panels
- Machinery power distribution
- Three-phase load management systems
FAQs
- 1. What is the role of the 125A MCCB in this DB?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions.
- 2. What is a VTPN distribution board?
Ans: It is a vertical distribution board designed for three-phase and neutral power distribution.
- 3. What does 6 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
- 4. What is the advantage of a double door enclosure?
Ans: It enhances safety by providing controlled access and additional protection for internal components.
- 5. What does IP43 protection mean?
Ans: It provides protection against dust and water splashes in semi-protected environments.
- 6. Can it be used outdoors?
Ans: It is suitable for covered or semi-protected installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 125A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 8+8+8 |
| Height(mm) | 588 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.