Lauritz Knudsen EXORA, Distribution Board (DB) VTPN, Double Door, IP43 MCCB I/C, 250A, 6 Way
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen EXORA, Distribution Board (DB) VTPN, Double Door, IP43 MCCB I/C, 250A, 6 Way
- Description
- Specifications
- Warranty
- Reviews
Description
About the Product
The Exora DB VTPN 6 Way Double Door IP43 distribution board with 250A MCCB incomer is a vertical three phase and neutral enclosure designed to support up to 6 outgoing circuits for modular protection devices such as MCBs, RCCBs, and isolators.
It is designed with provision for a 250A MCCB incomer, enabling reliable protection against overload and short circuit faults in high capacity applications. The double door construction combined with IP43 protection ensures enhanced safety and durability in semi protected environments.
How the Distribution Board Works
This VTPN distribution board operates as a structured three phase electrical system:
- The MCCB incomer up to 250A acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases and neutral
- Outgoing circuits are controlled through modular protection devices
- Ensures safe, organized, and balanced load distribution across phases
The MCCB enables centralized protection and improves overall system reliability.
Electrical Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 6 way
- Incomer: MCCB up to 250A
- Outgoing configuration: 6 + 6 + 6 modules
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal setup:
- Insulated busbar system for three phase distribution
- Neutral and earth bars with protection
- DIN rail mounting system for modular devices
- Adequate wiring and cable management space
- Circuit identification and labeling provision
It is designed as a ready to install enclosure ensuring organized wiring and easy installation.
Safety and Protection
- MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with live electrical parts
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Robust metal construction with protective coating
- Suitable for industrial and commercial environments
- Built for long term durability
Application Domains
- Industrial electrical distribution systems
- Commercial installations with high load requirements
- Electrical control panels
- Machinery and equipment power distribution
- High capacity sub distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 6 way circuit capacity for controlled outgoing circuits
- Supports MCCB incomer up to 250A
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible system for modular device installation
- Pre configured busbar, neutral and earth system
Applications
- Industrial plants
- Commercial facilities
- Electrical control panels
- Machinery and equipment distribution
- Three phase high load systems
FAQs
1. What is the function of the MCCB in this distribution board?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions and enabling safe isolation.
2. What does VTPN mean?
Ans: VTPN stands for Vertical Three Phase and Neutral, used for distributing three phase electrical power.
3. What does 6 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
4. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
5. Is the MCCB included in the distribution board?
Ans: The enclosure is designed for a 250A MCCB incomer, which is typically supplied separately.
6. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
7. Can it be used outdoors?
Ans: It is suitable for indoor or covered installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 250A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 8+8+8 |
| Height(mm) | 698 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Exora DB VTPN 6 Way Double Door IP43 distribution board with 250A MCCB incomer is a vertical three phase and neutral enclosure designed to support up to 6 outgoing circuits for modular protection devices such as MCBs, RCCBs, and isolators.
It is designed with provision for a 250A MCCB incomer, enabling reliable protection against overload and short circuit faults in high capacity applications. The double door construction combined with IP43 protection ensures enhanced safety and durability in semi protected environments.
How the Distribution Board Works
This VTPN distribution board operates as a structured three phase electrical system:
- The MCCB incomer up to 250A acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases and neutral
- Outgoing circuits are controlled through modular protection devices
- Ensures safe, organized, and balanced load distribution across phases
The MCCB enables centralized protection and improves overall system reliability.
Electrical Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 6 way
- Incomer: MCCB up to 250A
- Outgoing configuration: 6 + 6 + 6 modules
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal setup:
- Insulated busbar system for three phase distribution
- Neutral and earth bars with protection
- DIN rail mounting system for modular devices
- Adequate wiring and cable management space
- Circuit identification and labeling provision
It is designed as a ready to install enclosure ensuring organized wiring and easy installation.
Safety and Protection
- MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with live electrical parts
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Robust metal construction with protective coating
- Suitable for industrial and commercial environments
- Built for long term durability
Application Domains
- Industrial electrical distribution systems
- Commercial installations with high load requirements
- Electrical control panels
- Machinery and equipment power distribution
- High capacity sub distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 6 way circuit capacity for controlled outgoing circuits
- Supports MCCB incomer up to 250A
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible system for modular device installation
- Pre configured busbar, neutral and earth system
Applications
- Industrial plants
- Commercial facilities
- Electrical control panels
- Machinery and equipment distribution
- Three phase high load systems
FAQs
1. What is the function of the MCCB in this distribution board?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions and enabling safe isolation.
2. What does VTPN mean?
Ans: VTPN stands for Vertical Three Phase and Neutral, used for distributing three phase electrical power.
3. What does 6 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
4. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
5. Is the MCCB included in the distribution board?
Ans: The enclosure is designed for a 250A MCCB incomer, which is typically supplied separately.
6. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
7. Can it be used outdoors?
Ans: It is suitable for indoor or covered installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 6 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 250A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 8+8+8 |
| Height(mm) | 698 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.