Lauritz Knudsen EXORA, Isolator, 2 Pole, 240V AC, 40A
calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen EXORA, Isolator, 2 Pole, 240V AC, 40A
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Exora Isolator 40A DP 240V AC is a high-quality double pole switch disconnector designed to provide safe & reliable manual isolation of electrical circuits during maintenance, servicing, & emergency shutdown operations. Engineered for residential, commercial, & light industrial electrical installations, this isolator ensures complete disconnection of both phase & neutral conductors, preventing unwanted power flow & enhancing operational safety. With a 40A current rating, 240V AC operating voltage, & double pole configuration, it serves as an essential switching device for safe circuit isolation & power control applications.
How the Mechanism Works
The Exora Isolator functions as a manual switching device designed to safely disconnect electrical circuits.
• Manually operated ON/OFF switching mechanism.
• Physically separates electrical contacts when switched OFF.
• Completely disconnects both phase & neutral conductors.
• Prevents current flow during servicing & maintenance activities.
• Provides visible & reliable circuit isolation.
• Ensures safe shutdown of connected electrical equipment & installations.
• Does not provide overload or short-circuit protection & must be used alongside protective devices where required.
Electrical Configuration
This isolator is designed for safe switching & isolation in single-phase electrical systems.
• Rated current: 40A
• Pole configuration: Double Pole (DP)
• Rated voltage: 240V AC
• Suitable for single-phase installations
• Simultaneous phase & neutral disconnection
• Reliable manual switching operation
• Designed for circuit isolation & load disconnection applications
Construction & Design
Built for dependable operation & long-term reliability in modern electrical installations.
• High-quality flame-retardant insulated housing
• Compact modular design for efficient panel space utilization
• Robust switching mechanism
• Ergonomic operating handle for smooth operation
• Durable contact system for reliable switching performance
• Double pole configuration for complete circuit isolation
Safety & Protection
The isolator provides safe & effective electrical separation during maintenance & servicing.
• Complete electrical isolation capability
• Simultaneous phase & neutral disconnection
• Enhanced safety during maintenance procedures
• Prevents accidental energization of circuits
• Reliable manual switching operation
• Increased operator safety
• Suitable for emergency disconnection applications
• Supports safe servicing of connected equipment
Mounting & Durability
Designed for long-term operation across residential & commercial environments.
• Standard DIN rail mounting compatibility
• Quick & secure installation
• Compact space-saving design
• Durable industrial-grade construction
• Resistant to normal electrical & thermal stresses
• Low maintenance requirements
• Long operational service life
Application Domains
Suitable for a wide range of electrical isolation & switching applications.
• Residential distribution boards
• Commercial electrical panels
• Main switch applications
• Air conditioner isolation circuits
• Water heater isolation circuits
• Lighting control systems
• Appliance isolation circuits
• General electrical power distribution systems
Key Features
• Rated current: 40A
• Double Pole (DP) configuration
• Rated voltage: 240V AC
• Manual switch disconnector
• Complete phase & neutral isolation
• Safe & reliable switching operation
• DIN rail mounting compatible
• Compact modular construction
• Easy installation & maintenance
• Durable & robust design
• Long operational life
• Suitable for residential & commercial applications
Applications
• Residential distribution boards
• Commercial electrical panels
• Main switch isolation
• Air conditioner & appliance isolation
• Water heater circuits
• Lighting distribution systems
• Maintenance & servicing safety circuits
• General electrical installations
FAQs
1. What is a 40A isolator used for?
Ans: A 40A isolator is used to manually disconnect electrical circuits, allowing safe maintenance, servicing, & isolation of electrical equipment & installations.
2. What is the difference between an isolator & an MCB?
Ans: An isolator is used for manual circuit disconnection & isolation, while an MCB provides automatic protection against overload & short-circuit faults.
3. Why use a Double Pole (DP) isolator?
Ans: A Double Pole isolator disconnects both phase & neutral conductors simultaneously, ensuring complete circuit isolation & improved safety.
4. Does an isolator provide overload or short-circuit protection?
Ans: No, an isolator does not provide overload or short-circuit protection. Separate protective devices such as MCBs or RCCBs are required for fault protection.
5. Where is this isolator commonly installed?
Ans: It is commonly installed in residential distribution boards, commercial electrical panels, appliance circuits, air conditioning systems, water heaters, & general electrical installations.
6. Can it be used as a main switch?
Ans: Yes, a 40A DP isolator is commonly used as a main switch for safe manual control & isolation of electrical circuits.
7. How is the isolator mounted?
Ans: The isolator is designed for easy installation on standard DIN rails inside distribution boards & electrical panels.
8. Why is complete circuit isolation important?
Ans: Complete isolation ensures that no electrical current reaches the circuit during maintenance or servicing, significantly improving user safety & preventing accidental electric shock.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +50°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Conformance to standards | EN/IEC 60947-3 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Impulse Voltage | 4kV |
| Current Rating | 40A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | EN/IEC 60947-3 |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Exora Isolator 40A DP 240V AC is a high-quality double pole switch disconnector designed to provide safe & reliable manual isolation of electrical circuits during maintenance, servicing, & emergency shutdown operations. Engineered for residential, commercial, & light industrial electrical installations, this isolator ensures complete disconnection of both phase & neutral conductors, preventing unwanted power flow & enhancing operational safety. With a 40A current rating, 240V AC operating voltage, & double pole configuration, it serves as an essential switching device for safe circuit isolation & power control applications.
How the Mechanism Works
The Exora Isolator functions as a manual switching device designed to safely disconnect electrical circuits.
• Manually operated ON/OFF switching mechanism.
• Physically separates electrical contacts when switched OFF.
• Completely disconnects both phase & neutral conductors.
• Prevents current flow during servicing & maintenance activities.
• Provides visible & reliable circuit isolation.
• Ensures safe shutdown of connected electrical equipment & installations.
• Does not provide overload or short-circuit protection & must be used alongside protective devices where required.
Electrical Configuration
This isolator is designed for safe switching & isolation in single-phase electrical systems.
• Rated current: 40A
• Pole configuration: Double Pole (DP)
• Rated voltage: 240V AC
• Suitable for single-phase installations
• Simultaneous phase & neutral disconnection
• Reliable manual switching operation
• Designed for circuit isolation & load disconnection applications
Construction & Design
Built for dependable operation & long-term reliability in modern electrical installations.
• High-quality flame-retardant insulated housing
• Compact modular design for efficient panel space utilization
• Robust switching mechanism
• Ergonomic operating handle for smooth operation
• Durable contact system for reliable switching performance
• Double pole configuration for complete circuit isolation
Safety & Protection
The isolator provides safe & effective electrical separation during maintenance & servicing.
• Complete electrical isolation capability
• Simultaneous phase & neutral disconnection
• Enhanced safety during maintenance procedures
• Prevents accidental energization of circuits
• Reliable manual switching operation
• Increased operator safety
• Suitable for emergency disconnection applications
• Supports safe servicing of connected equipment
Mounting & Durability
Designed for long-term operation across residential & commercial environments.
• Standard DIN rail mounting compatibility
• Quick & secure installation
• Compact space-saving design
• Durable industrial-grade construction
• Resistant to normal electrical & thermal stresses
• Low maintenance requirements
• Long operational service life
Application Domains
Suitable for a wide range of electrical isolation & switching applications.
• Residential distribution boards
• Commercial electrical panels
• Main switch applications
• Air conditioner isolation circuits
• Water heater isolation circuits
• Lighting control systems
• Appliance isolation circuits
• General electrical power distribution systems
Key Features
• Rated current: 40A
• Double Pole (DP) configuration
• Rated voltage: 240V AC
• Manual switch disconnector
• Complete phase & neutral isolation
• Safe & reliable switching operation
• DIN rail mounting compatible
• Compact modular construction
• Easy installation & maintenance
• Durable & robust design
• Long operational life
• Suitable for residential & commercial applications
Applications
• Residential distribution boards
• Commercial electrical panels
• Main switch isolation
• Air conditioner & appliance isolation
• Water heater circuits
• Lighting distribution systems
• Maintenance & servicing safety circuits
• General electrical installations
FAQs
1. What is a 40A isolator used for?
Ans: A 40A isolator is used to manually disconnect electrical circuits, allowing safe maintenance, servicing, & isolation of electrical equipment & installations.
2. What is the difference between an isolator & an MCB?
Ans: An isolator is used for manual circuit disconnection & isolation, while an MCB provides automatic protection against overload & short-circuit faults.
3. Why use a Double Pole (DP) isolator?
Ans: A Double Pole isolator disconnects both phase & neutral conductors simultaneously, ensuring complete circuit isolation & improved safety.
4. Does an isolator provide overload or short-circuit protection?
Ans: No, an isolator does not provide overload or short-circuit protection. Separate protective devices such as MCBs or RCCBs are required for fault protection.
5. Where is this isolator commonly installed?
Ans: It is commonly installed in residential distribution boards, commercial electrical panels, appliance circuits, air conditioning systems, water heaters, & general electrical installations.
6. Can it be used as a main switch?
Ans: Yes, a 40A DP isolator is commonly used as a main switch for safe manual control & isolation of electrical circuits.
7. How is the isolator mounted?
Ans: The isolator is designed for easy installation on standard DIN rails inside distribution boards & electrical panels.
8. Why is complete circuit isolation important?
Ans: Complete isolation ensures that no electrical current reaches the circuit during maintenance or servicing, significantly improving user safety & preventing accidental electric shock.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +50°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Conformance to standards | EN/IEC 60947-3 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Impulse Voltage | 4kV |
| Current Rating | 40A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | EN/IEC 60947-3 |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.