Lauritz Knudsen EXORA, MCB, 2 Pole, 240V AC, 10kA, C Curve, 63A
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen EXORA, MCB, 2 Pole, 240V AC, 10kA, C Curve, 63A
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
Exora MCB 63A DP 240V AC 10kA C Curve is a double pole miniature circuit breaker designed to protect electrical circuits from overload & short circuit conditions. It is suitable for high-load residential, commercial, & industrial applications involving inductive equipment.
How the Mechanism Works
The MCB operates using a thermal magnetic protection mechanism. The thermal element responds to overload conditions over time, while the magnetic mechanism ensures instantaneous tripping during short circuit faults. In the double pole configuration, both phase & neutral disconnect simultaneously for complete circuit isolation.
Electrical Configuration
This is a double pole (DP) MCB rated at 63A current, suitable for 240V AC systems, with a 10kA breaking capacity. It features a C curve tripping characteristic, making it ideal for circuits with moderate to high inrush current such as compressors, motors, pumps, & heavy-duty inductive loads.
• Safety / protection aspects
• The double pole design ensures complete isolation of both phase & neutral conductors, significantly enhancing safety during operation, maintenance, & fault conditions. It protects wiring, electrical systems, & equipment while reducing the risk of electrical hazards & fire.
Construction & Design
A compact insulating body integrates the operating mechanism, contacts, arc-control components, terminals, & trip elements for reliable circuit protection.
Safety & Protection
Provides circuit isolation & overcurrent protection when correctly selected, coordinated, installed, & operated within its published ratings.
Mounting & Durability
Designed for DIN rail mounting, the breaker allows easy installation in distribution boards & control panels. Its heavy-duty construction ensures reliable long-term performance under high-load conditions.
Application Domains
Suitable for high-load residential & commercial installations such as main power circuits, air conditioners, compressors, motors, pumps, & industrial electrical systems requiring full isolation.
Key Features
• Rated current: 63A
• Double pole (DP) configuration
• Rated voltage: 240V AC
• Breaking capacity: 10kA
• C curve tripping characteristic
• Thermal magnetic protection mechanism
• Simultaneous phase & neutral disconnection
• DIN rail mounting compatible
• Suitable for moderate to high inductive load applications
• Heavy-duty & durable design
Applications
• Residential distribution boards
• Main power circuits
• Air conditioners & compressors
• Motor & pump systems
• Commercial & industrial electrical panels
FAQs
1. What is a 63A DP C curve MCB used for?
Ans: It is used for high-load circuits with moderate to high inrush current such as compressors, motors, & pump systems requiring full isolation.
2. What is C curve in MCB?
Ans: C curve allows higher inrush current before tripping compared to B curve, making it suitable for inductive loads.
3. Why use a double pole MCB?
Ans: It disconnects both phase & neutral simultaneously, ensuring safer operation & complete circuit isolation.
4. What is 10kA breaking capacity?
Ans: It is the maximum fault current the MCB can safely interrupt.
5. Can it be used in homes?
Ans: Yes, it is suitable for high-load residential applications such as main circuits & heavy appliances.
6. How is it installed?
Ans: It is mounted on standard DIN rails inside distribution boards.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +70° C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Conformance to standards | IS/IEC 60898-1 IEC 60947-2 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 10kA as per IS/IEC 60898-1 10kA as per IEC 60947-2 |
| Rated Impulse Voltage | 4kV |
| Current Rating | 63A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | IS/IEC 60898-1 IEC 60947-2 |
| Tripping Characteristic | C Curve |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
Exora MCB 63A DP 240V AC 10kA C Curve is a double pole miniature circuit breaker designed to protect electrical circuits from overload & short circuit conditions. It is suitable for high-load residential, commercial, & industrial applications involving inductive equipment.
How the Mechanism Works
The MCB operates using a thermal magnetic protection mechanism. The thermal element responds to overload conditions over time, while the magnetic mechanism ensures instantaneous tripping during short circuit faults. In the double pole configuration, both phase & neutral disconnect simultaneously for complete circuit isolation.
Electrical Configuration
This is a double pole (DP) MCB rated at 63A current, suitable for 240V AC systems, with a 10kA breaking capacity. It features a C curve tripping characteristic, making it ideal for circuits with moderate to high inrush current such as compressors, motors, pumps, & heavy-duty inductive loads.
• Safety / protection aspects
• The double pole design ensures complete isolation of both phase & neutral conductors, significantly enhancing safety during operation, maintenance, & fault conditions. It protects wiring, electrical systems, & equipment while reducing the risk of electrical hazards & fire.
Construction & Design
A compact insulating body integrates the operating mechanism, contacts, arc-control components, terminals, & trip elements for reliable circuit protection.
Safety & Protection
Provides circuit isolation & overcurrent protection when correctly selected, coordinated, installed, & operated within its published ratings.
Mounting & Durability
Designed for DIN rail mounting, the breaker allows easy installation in distribution boards & control panels. Its heavy-duty construction ensures reliable long-term performance under high-load conditions.
Application Domains
Suitable for high-load residential & commercial installations such as main power circuits, air conditioners, compressors, motors, pumps, & industrial electrical systems requiring full isolation.
Key Features
• Rated current: 63A
• Double pole (DP) configuration
• Rated voltage: 240V AC
• Breaking capacity: 10kA
• C curve tripping characteristic
• Thermal magnetic protection mechanism
• Simultaneous phase & neutral disconnection
• DIN rail mounting compatible
• Suitable for moderate to high inductive load applications
• Heavy-duty & durable design
Applications
• Residential distribution boards
• Main power circuits
• Air conditioners & compressors
• Motor & pump systems
• Commercial & industrial electrical panels
FAQs
1. What is a 63A DP C curve MCB used for?
Ans: It is used for high-load circuits with moderate to high inrush current such as compressors, motors, & pump systems requiring full isolation.
2. What is C curve in MCB?
Ans: C curve allows higher inrush current before tripping compared to B curve, making it suitable for inductive loads.
3. Why use a double pole MCB?
Ans: It disconnects both phase & neutral simultaneously, ensuring safer operation & complete circuit isolation.
4. What is 10kA breaking capacity?
Ans: It is the maximum fault current the MCB can safely interrupt.
5. Can it be used in homes?
Ans: Yes, it is suitable for high-load residential applications such as main circuits & heavy appliances.
6. How is it installed?
Ans: It is mounted on standard DIN rails inside distribution boards.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +70° C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Conformance to standards | IS/IEC 60898-1 IEC 60947-2 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 10kA as per IS/IEC 60898-1 10kA as per IEC 60947-2 |
| Rated Impulse Voltage | 4kV |
| Current Rating | 63A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | IS/IEC 60898-1 IEC 60947-2 |
| Tripping Characteristic | C Curve |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.