The Exora RCCB 100A DP 240V AC 300mA is a high-performance Residual Current Circuit Breaker designed to provide reliable protection against earth leakage faults in low-voltage electrical systems. Engineered for commercial, industrial, & upstream distribution applications, this RCCB continuously monitors current flow & instantly disconnects the power supply when leakage current is detected. With a 100A current rating, 240V AC operating voltage, double pole configuration, & 300mA sensitivity, it is specifically designed to help prevent fire hazards caused by insulation failures & leakage currents. The device offers dependable protection for electrical installations & equipment while ensuring safe & reliable operation of power distribution systems.
How the Mechanism Works
The Exora RCCB utilizes an advanced residual current detection mechanism to monitor electrical safety continuously.
• Continuously compares current flowing through live & neutral conductors.
• Detects any imbalance caused by leakage current to earth.
• Trips instantly when leakage current exceeds 300mA.
• Interrupts the electrical supply before leakage faults can cause equipment damage or fire hazards.
• Provides rapid fault detection & circuit isolation.
• Reduces risks associated with insulation deterioration & electrical leakage.
Electrical Configuration
This RCCB is designed for fire protection & leakage current monitoring in single-phase electrical systems.
• Rated current: 100A
• Pole configuration: Double Pole (DP)
• Rated voltage: 240V AC
• Sensitivity: 300mA
• Residual current protection functionality
• Suitable for high-load commercial, industrial, & upstream protection applications
• Designed for enhanced fire safety & fault protection
Construction & Design
Built for dependable operation & long-term reliability in modern electrical installations.
• High-quality flame-retardant insulated housing
• Compact modular construction for space-efficient installation
• Precision-engineered sensing mechanism
• Ergonomic operating handle for easy switching & resetting
• Integrated test function for routine safety verification
• Double pole configuration for complete circuit isolation
Safety & Protection
The RCCB provides comprehensive protection against leakage-related electrical hazards.
• Earth leakage protection
• Fire hazard protection caused by insulation faults
• Fast fault detection & disconnection
• Protection for electrical equipment & installations
• Reduced risk of electrical fires due to leakage currents
• Enhanced safety for commercial & industrial applications
• Reliable protection against insulation deterioration
• Improved electrical system reliability
Mounting & Durability
Designed for long-term operation in demanding electrical environments.
• Standard DIN rail mounting compatibility
• Quick & secure installation
• Compact space-saving design
• Heavy-duty industrial-grade construction
• Resistant to electrical & thermal stresses
• Low maintenance requirements
• Long operational service life with consistent performance
Application Domains
Suitable for a wide range of commercial & industrial electrical installations requiring fire protection through leakage current monitoring.
• Main distribution boards
• Industrial plants & factories
• Commercial buildings & complexes
• High-load electrical circuits
• Sub-main & upstream protection systems
• Manufacturing facilities
• Electrical distribution networks
• Fire safety applications
Key Features
• Rated current: 100A
• Double Pole (DP) configuration
• Rated voltage: 240V AC
• Sensitivity: 300mA
• Residual current protection (earth leakage protection)
• Fire hazard protection due to leakage currents
• Fast & reliable tripping mechanism
• Complete live & neutral isolation
• DIN rail mounting compatible
• Compact modular construction
• Heavy-duty & durable design
• Suitable for commercial & industrial applications
Applications
• Main distribution boards
• Industrial & commercial systems
• High-load electrical circuits
• Sub-main & upstream protection
• Fire safety electrical installations
• Manufacturing facilities
• Distribution network protection
• Leakage monitoring systems
FAQs
1. What is a 100A 300mA RCCB used for?
Ans: A 100A 300mA RCCB is primarily used for fire protection & leakage current detection in high-load electrical systems, helping prevent insulation-related fire hazards.
2. What does 300mA sensitivity mean?
Ans: A 300mA sensitivity means the RCCB will trip when leakage current exceeds 300 milliamperes, providing effective protection against leakage-related fire risks.
3. How is a 300mA RCCB different from a 30mA RCCB?
Ans: A 300mA RCCB is mainly designed for fire protection & upstream circuit protection, whereas a 30mA RCCB is intended for personal protection against electric shock.
4. Why use a Double Pole (DP) RCCB?
Ans: A Double Pole RCCB disconnects both live & neutral conductors simultaneously, ensuring complete circuit isolation & improved safety.
5. What is the difference between an RCCB & an MCB?
Ans: An RCCB protects against earth leakage currents, while an MCB protects against overload & short-circuit conditions.
6. Does the RCCB protect against overloads?
Ans: No, an RCCB only protects against leakage currents. Overload & short-circuit protection require an MCB or RCBO in combination with the RCCB.
7. Where is this RCCB commonly installed?
Ans: It is commonly installed in industrial plants, commercial buildings, main distribution boards, high-load electrical circuits, upstream protection systems, & fire safety installations requiring leakage monitoring.
8. How is the RCCB mounted?
Ans: The RCCB is designed for easy installation on standard DIN rails inside distribution boards & electrical panels.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +55°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (Rigid) 35 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20000 |
| No. of Poles | DP |
| Conformance to standards | IS 12640-1 IEC 61008-1 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1 kA |
| Rated Impulse Voltage | 4kV |
| Rated Conditional SC Current | 10 kA |
| Current Rating | 100A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | IS 12640-1 IEC 61008-1 |
| Sensitivity | 300mA |
| Length(mm) | 77.1 |
| Height(mm) | 83 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Exora RCCB 100A DP 240V AC 300mA is a high-performance Residual Current Circuit Breaker designed to provide reliable protection against earth leakage faults in low-voltage electrical systems. Engineered for commercial, industrial, & upstream distribution applications, this RCCB continuously monitors current flow & instantly disconnects the power supply when leakage current is detected. With a 100A current rating, 240V AC operating voltage, double pole configuration, & 300mA sensitivity, it is specifically designed to help prevent fire hazards caused by insulation failures & leakage currents. The device offers dependable protection for electrical installations & equipment while ensuring safe & reliable operation of power distribution systems.
How the Mechanism Works
The Exora RCCB utilizes an advanced residual current detection mechanism to monitor electrical safety continuously.
• Continuously compares current flowing through live & neutral conductors.
• Detects any imbalance caused by leakage current to earth.
• Trips instantly when leakage current exceeds 300mA.
• Interrupts the electrical supply before leakage faults can cause equipment damage or fire hazards.
• Provides rapid fault detection & circuit isolation.
• Reduces risks associated with insulation deterioration & electrical leakage.
Electrical Configuration
This RCCB is designed for fire protection & leakage current monitoring in single-phase electrical systems.
• Rated current: 100A
• Pole configuration: Double Pole (DP)
• Rated voltage: 240V AC
• Sensitivity: 300mA
• Residual current protection functionality
• Suitable for high-load commercial, industrial, & upstream protection applications
• Designed for enhanced fire safety & fault protection
Construction & Design
Built for dependable operation & long-term reliability in modern electrical installations.
• High-quality flame-retardant insulated housing
• Compact modular construction for space-efficient installation
• Precision-engineered sensing mechanism
• Ergonomic operating handle for easy switching & resetting
• Integrated test function for routine safety verification
• Double pole configuration for complete circuit isolation
Safety & Protection
The RCCB provides comprehensive protection against leakage-related electrical hazards.
• Earth leakage protection
• Fire hazard protection caused by insulation faults
• Fast fault detection & disconnection
• Protection for electrical equipment & installations
• Reduced risk of electrical fires due to leakage currents
• Enhanced safety for commercial & industrial applications
• Reliable protection against insulation deterioration
• Improved electrical system reliability
Mounting & Durability
Designed for long-term operation in demanding electrical environments.
• Standard DIN rail mounting compatibility
• Quick & secure installation
• Compact space-saving design
• Heavy-duty industrial-grade construction
• Resistant to electrical & thermal stresses
• Low maintenance requirements
• Long operational service life with consistent performance
Application Domains
Suitable for a wide range of commercial & industrial electrical installations requiring fire protection through leakage current monitoring.
• Main distribution boards
• Industrial plants & factories
• Commercial buildings & complexes
• High-load electrical circuits
• Sub-main & upstream protection systems
• Manufacturing facilities
• Electrical distribution networks
• Fire safety applications
Key Features
• Rated current: 100A
• Double Pole (DP) configuration
• Rated voltage: 240V AC
• Sensitivity: 300mA
• Residual current protection (earth leakage protection)
• Fire hazard protection due to leakage currents
• Fast & reliable tripping mechanism
• Complete live & neutral isolation
• DIN rail mounting compatible
• Compact modular construction
• Heavy-duty & durable design
• Suitable for commercial & industrial applications
Applications
• Main distribution boards
• Industrial & commercial systems
• High-load electrical circuits
• Sub-main & upstream protection
• Fire safety electrical installations
• Manufacturing facilities
• Distribution network protection
• Leakage monitoring systems
FAQs
1. What is a 100A 300mA RCCB used for?
Ans: A 100A 300mA RCCB is primarily used for fire protection & leakage current detection in high-load electrical systems, helping prevent insulation-related fire hazards.
2. What does 300mA sensitivity mean?
Ans: A 300mA sensitivity means the RCCB will trip when leakage current exceeds 300 milliamperes, providing effective protection against leakage-related fire risks.
3. How is a 300mA RCCB different from a 30mA RCCB?
Ans: A 300mA RCCB is mainly designed for fire protection & upstream circuit protection, whereas a 30mA RCCB is intended for personal protection against electric shock.
4. Why use a Double Pole (DP) RCCB?
Ans: A Double Pole RCCB disconnects both live & neutral conductors simultaneously, ensuring complete circuit isolation & improved safety.
5. What is the difference between an RCCB & an MCB?
Ans: An RCCB protects against earth leakage currents, while an MCB protects against overload & short-circuit conditions.
6. Does the RCCB protect against overloads?
Ans: No, an RCCB only protects against leakage currents. Overload & short-circuit protection require an MCB or RCBO in combination with the RCCB.
7. Where is this RCCB commonly installed?
Ans: It is commonly installed in industrial plants, commercial buildings, main distribution boards, high-load electrical circuits, upstream protection systems, & fire safety installations requiring leakage monitoring.
8. How is the RCCB mounted?
Ans: The RCCB is designed for easy installation on standard DIN rails inside distribution boards & electrical panels.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +55°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 50 Sq. mm (Rigid) 35 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20000 |
| No. of Poles | DP |
| Conformance to standards | IS 12640-1 IEC 61008-1 |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Residual Making & Breaking capacity | 1 kA |
| Rated Impulse Voltage | 4kV |
| Rated Conditional SC Current | 10 kA |
| Current Rating | 100A |
| Rated Operational voltage (Ue) | 240V |
| Conformance to Standards | IS 12640-1 IEC 61008-1 |
| Sensitivity | 300mA |
| Length(mm) | 77.1 |
| Height(mm) | 83 |
| Breadth(mm) | 35 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.