About the Product
The Lauritz Knudsen MN-140 FASD Starter (90–150A, 415V AC) is a premium heavy-duty motor starter engineered for efficient & controlled starting of large three phase induction motors. It uses the Fully Automatic Star Delta (FASD) method to significantly reduce high inrush current & mechanical stress during motor startup, ensuring smooth performance & extended equipment life.
Belonging to the MN series, this starter is specifically built for demanding industrial environments. It integrates contactors, a timer system, & a thermal overload relay into a robust enclosure, delivering a complete & reliable solution for motor control & protection in high-load applications.
Purpose & Function
This FASD starter provides advanced motor starting & protection:
• Starts motors using star-delta method to reduce starting current
• Automatically switches from star to delta mode after startup
• Minimizes mechanical & electrical stress on motors
• Provides overload protection using a thermal relay
• Ensures safe, efficient, & stable motor operation
Technical Specifications
• Type: FASD (Fully Automatic Star Delta) Starter
• Current rating: 90–150A
• Rated voltage: 415V AC
• Phase: Three phase
• Model: MN-140
• Function: Motor starting, control, & protection
Construction & Design
The starter is engineered for high-performance industrial use:
• Rugged & heavy-duty enclosure
• Integrated contactors, timer, & thermal overload relay
• Automatic star-to-delta transition system
• High-quality components for long service life
• Suitable for panel mounting or standalone installation
Safety & Protection
• Thermal overload relay protects against excessive current
• Star-delta starting reduces stress on electrical systems
• Prevents overheating & damage to motors
• Ensures safe startup & controlled shutdown
• Enhances reliability of large motor operations
Mounting & Installation
• Suitable for panel or surface mounting
• Easy installation & wiring
• Compatible with standard industrial electrical systems
• Ideal for large motor control panels
• Supports clean & organized installation
Application Areas
• Heavy industrial machinery
• Large pumps & compressors
• Conveyor & material handling systems
• HVAC & industrial ventilation plants
• Manufacturing & processing facilities
• High-power motor-driven applications
Key Features
• 90–150A rating for very high-capacity motors
• 415V AC operation for three phase systems
• Star-delta starting reduces inrush current
• Fully automatic operation with timer-based switching
• Built-in thermal overload protection
• Durable & heavy-duty industrial design
Applications
• Industrial motor control panels
• Large pump & compressor installations
• Conveyor & heavy machinery systems
• HVAC & large ventilation systems
• Manufacturing plants & automation setups
FAQs
1. What is an FASD starter?
Ans: An FASD (Fully Automatic Star Delta) starter begins motor operation in star mode & automatically switches to delta mode to reduce starting current.
2. What does 90–150A mean?
Ans: It indicates the high current range suitable for very large motors & heavy-duty applications.
3. Why use a star-delta starter instead of DOL?
Ans: A star-delta starter reduces starting current & mechanical stress, improving motor lifespan & system efficiency.
4. What is the role of the timer?
Ans: The timer controls the automatic transition from star to delta during motor startup.
5. Is this suitable for heavy industrial applications?
Ans: Yes, it is specifically designed for large motors used in industrial machinery & high-load operations.
6. What voltage does it support?
Ans: It operates at 415V AC, which is standard for three phase industrial systems.
7. Why is overload protection important?
Ans: It prevents motor damage due to excessive current & overheating, ensuring safe & reliable operation.
Overview
| Relay Range (A) | 90-150A |
|---|---|
| Relay | MN 12L |
| Contactor | MNX 140 |
| Coil Voltage | 415 V AC |
| Conformance to Standards | IS/IEC 60947-4-1, IEC 60947-4-1 |
| Ambient temperature | -5 to 55 deg C |
| Degree of protection | IP 54 |
| Discount Percentage | Between 0-10 % |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Lauritz Knudsen MN-140 FASD Starter (90–150A, 415V AC) is a premium heavy-duty motor starter engineered for efficient & controlled starting of large three phase induction motors. It uses the Fully Automatic Star Delta (FASD) method to significantly reduce high inrush current & mechanical stress during motor startup, ensuring smooth performance & extended equipment life.
Belonging to the MN series, this starter is specifically built for demanding industrial environments. It integrates contactors, a timer system, & a thermal overload relay into a robust enclosure, delivering a complete & reliable solution for motor control & protection in high-load applications.
Purpose & Function
This FASD starter provides advanced motor starting & protection:
• Starts motors using star-delta method to reduce starting current
• Automatically switches from star to delta mode after startup
• Minimizes mechanical & electrical stress on motors
• Provides overload protection using a thermal relay
• Ensures safe, efficient, & stable motor operation
Technical Specifications
• Type: FASD (Fully Automatic Star Delta) Starter
• Current rating: 90–150A
• Rated voltage: 415V AC
• Phase: Three phase
• Model: MN-140
• Function: Motor starting, control, & protection
Construction & Design
The starter is engineered for high-performance industrial use:
• Rugged & heavy-duty enclosure
• Integrated contactors, timer, & thermal overload relay
• Automatic star-to-delta transition system
• High-quality components for long service life
• Suitable for panel mounting or standalone installation
Safety & Protection
• Thermal overload relay protects against excessive current
• Star-delta starting reduces stress on electrical systems
• Prevents overheating & damage to motors
• Ensures safe startup & controlled shutdown
• Enhances reliability of large motor operations
Mounting & Installation
• Suitable for panel or surface mounting
• Easy installation & wiring
• Compatible with standard industrial electrical systems
• Ideal for large motor control panels
• Supports clean & organized installation
Application Areas
• Heavy industrial machinery
• Large pumps & compressors
• Conveyor & material handling systems
• HVAC & industrial ventilation plants
• Manufacturing & processing facilities
• High-power motor-driven applications
Key Features
• 90–150A rating for very high-capacity motors
• 415V AC operation for three phase systems
• Star-delta starting reduces inrush current
• Fully automatic operation with timer-based switching
• Built-in thermal overload protection
• Durable & heavy-duty industrial design
Applications
• Industrial motor control panels
• Large pump & compressor installations
• Conveyor & heavy machinery systems
• HVAC & large ventilation systems
• Manufacturing plants & automation setups
FAQs
1. What is an FASD starter?
Ans: An FASD (Fully Automatic Star Delta) starter begins motor operation in star mode & automatically switches to delta mode to reduce starting current.
2. What does 90–150A mean?
Ans: It indicates the high current range suitable for very large motors & heavy-duty applications.
3. Why use a star-delta starter instead of DOL?
Ans: A star-delta starter reduces starting current & mechanical stress, improving motor lifespan & system efficiency.
4. What is the role of the timer?
Ans: The timer controls the automatic transition from star to delta during motor startup.
5. Is this suitable for heavy industrial applications?
Ans: Yes, it is specifically designed for large motors used in industrial machinery & high-load operations.
6. What voltage does it support?
Ans: It operates at 415V AC, which is standard for three phase industrial systems.
7. Why is overload protection important?
Ans: It prevents motor damage due to excessive current & overheating, ensuring safe & reliable operation.
Overview
| Relay Range (A) | 90-150A |
|---|---|
| Relay | MN 12L |
| Contactor | MNX 140 |
| Coil Voltage | 415 V AC |
| Conformance to Standards | IS/IEC 60947-4-1, IEC 60947-4-1 |
| Ambient temperature | -5 to 55 deg C |
| Degree of protection | IP 54 |
| Discount Percentage | Between 0-10 % |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.