The Lauritz Knudsen MN-16 FASD Starter (9–15A, 415V AC) is a compact & efficient motor starter designed for controlled & reliable starting of small to medium three phase induction motors. It utilizes the Fully Automatic Star Delta (FASD) starting method, which reduces inrush current & mechanical stress during startup, ensuring smooth operation & longer motor life.
As part of the MN series, this starter integrates essential components such as contactors, a timer, & a thermal overload relay within a compact enclosure. It offers a complete solution for motor control, protection, & efficient operation in industrial & commercial environments.
Purpose & Function
This FASD starter is designed for advanced motor starting & protection:
• Starts motors using the star-delta method to reduce starting current
• Automatically switches from star to delta mode
• Minimizes electrical & mechanical stress on motors
• Provides overload protection using a thermal relay
• Ensures safe & efficient motor operation
Electrical Configuration
• Type: FASD (Fully Automatic Star Delta) Starter
• Current rating: 9–15A
• Rated voltage: 415V AC
• Phase: Three phase
• Model: MN-16
• Function: Motor starting, control, & protection
Construction & Design
The starter is engineered for durability & reliable operation:
• Compact & robust construction
• Integrated contactors, timer, & thermal overload relay
• Automatic star-to-delta transition for smooth startup
• High-quality internal components
• Suitable for panel mounting or standalone installation
Safety & Protection
• Thermal overload relay protects against excessive current
• Star-delta starting reduces electrical stress on the system
• Prevents motor overheating & damage
• Ensures safe startup & shutdown
• Enhances reliability & operational safety
Mounting & Installation
• Suitable for panel or surface mounting
• Easy & quick installation
• Compatible with standard industrial wiring systems
• Ideal for motor control panels
• Supports clean & organized wiring layouts
Application Domains
• Small industrial machinery
• Pumps & irrigation systems
• HVAC systems
• Compressors & conveyors
• Manufacturing units
• Commercial motor applications
Key Features
• 9–15A rating for small to medium motors
• 415V AC operation for three phase systems
• Star-delta starting reduces inrush current
• Fully automatic operation with timer control
• Built-in thermal overload protection
• Compact & durable design
Applications
• Industrial motor control panels
• Pump & compressor systems
• Conveyor & machinery applications
• HVAC & ventilation systems
• Manufacturing & automation setups
FAQs
1. What is an FASD starter?
Ans: An FASD (Fully Automatic Star Delta) starter starts the motor in star mode & automatically switches to delta mode to reduce starting current.
2. What does 9–15A mean?
Ans: It indicates the current range the starter can safely handle, suitable for small to medium motors.
3. Why use a star-delta starter instead of DOL?
Ans: It reduces starting current & mechanical stress, improving motor life & system efficiency.
4. What is the role of the timer?
Ans: The timer controls the automatic transition from star to delta mode during motor startup.
5. Is this suitable for three phase motors?
Ans: Yes, it is specifically designed for three phase induction motors.
6. Can it be used in industrial applications?
Ans: Yes, it is suitable for industrial & commercial motor control systems.
7. Why is overload protection important?
Ans: It protects the motor from excessive current & overheating, ensuring safe & reliable operation.
Overview
| Relay Range (A) | 9-15A |
|---|---|
| Relay | MN 2 |
| Contactor | MNX 18 |
| Coil Voltage | 415 V AC |
| Conformance to Standards | IS/IEC 60947-4-1, IEC 60947-4-1 |
| Ambient temperature | -5 to 55 deg C |
| Degree of protection | IP 54 |
| Discount Percentage | Between 0-10 % |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Lauritz Knudsen MN-16 FASD Starter (9–15A, 415V AC) is a compact & efficient motor starter designed for controlled & reliable starting of small to medium three phase induction motors. It utilizes the Fully Automatic Star Delta (FASD) starting method, which reduces inrush current & mechanical stress during startup, ensuring smooth operation & longer motor life.
As part of the MN series, this starter integrates essential components such as contactors, a timer, & a thermal overload relay within a compact enclosure. It offers a complete solution for motor control, protection, & efficient operation in industrial & commercial environments.
Purpose & Function
This FASD starter is designed for advanced motor starting & protection:
• Starts motors using the star-delta method to reduce starting current
• Automatically switches from star to delta mode
• Minimizes electrical & mechanical stress on motors
• Provides overload protection using a thermal relay
• Ensures safe & efficient motor operation
Electrical Configuration
• Type: FASD (Fully Automatic Star Delta) Starter
• Current rating: 9–15A
• Rated voltage: 415V AC
• Phase: Three phase
• Model: MN-16
• Function: Motor starting, control, & protection
Construction & Design
The starter is engineered for durability & reliable operation:
• Compact & robust construction
• Integrated contactors, timer, & thermal overload relay
• Automatic star-to-delta transition for smooth startup
• High-quality internal components
• Suitable for panel mounting or standalone installation
Safety & Protection
• Thermal overload relay protects against excessive current
• Star-delta starting reduces electrical stress on the system
• Prevents motor overheating & damage
• Ensures safe startup & shutdown
• Enhances reliability & operational safety
Mounting & Installation
• Suitable for panel or surface mounting
• Easy & quick installation
• Compatible with standard industrial wiring systems
• Ideal for motor control panels
• Supports clean & organized wiring layouts
Application Domains
• Small industrial machinery
• Pumps & irrigation systems
• HVAC systems
• Compressors & conveyors
• Manufacturing units
• Commercial motor applications
Key Features
• 9–15A rating for small to medium motors
• 415V AC operation for three phase systems
• Star-delta starting reduces inrush current
• Fully automatic operation with timer control
• Built-in thermal overload protection
• Compact & durable design
Applications
• Industrial motor control panels
• Pump & compressor systems
• Conveyor & machinery applications
• HVAC & ventilation systems
• Manufacturing & automation setups
FAQs
1. What is an FASD starter?
Ans: An FASD (Fully Automatic Star Delta) starter starts the motor in star mode & automatically switches to delta mode to reduce starting current.
2. What does 9–15A mean?
Ans: It indicates the current range the starter can safely handle, suitable for small to medium motors.
3. Why use a star-delta starter instead of DOL?
Ans: It reduces starting current & mechanical stress, improving motor life & system efficiency.
4. What is the role of the timer?
Ans: The timer controls the automatic transition from star to delta mode during motor startup.
5. Is this suitable for three phase motors?
Ans: Yes, it is specifically designed for three phase induction motors.
6. Can it be used in industrial applications?
Ans: Yes, it is suitable for industrial & commercial motor control systems.
7. Why is overload protection important?
Ans: It protects the motor from excessive current & overheating, ensuring safe & reliable operation.
Overview
| Relay Range (A) | 9-15A |
|---|---|
| Relay | MN 2 |
| Contactor | MNX 18 |
| Coil Voltage | 415 V AC |
| Conformance to Standards | IS/IEC 60947-4-1, IEC 60947-4-1 |
| Ambient temperature | -5 to 55 deg C |
| Degree of protection | IP 54 |
| Discount Percentage | Between 0-10 % |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.