Lauritz Knudsen MNX Power Contactor 50A, 3 Pole, 110V AC | AC1 Rating - 85A | AC3 Rating - 50A | Electrical Coil | Click fit type construction up to 40A
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen MNX Power Contactor 50A, 3 Pole, 110V AC | AC1 Rating - 85A | AC3 Rating - 50A | Electrical Coil | Click fit type construction up to 40A
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Lauritz Knudsen MNX Contactor 50A 3P 415V AC (AC 3) with 110V AC Coil (50–60 Hz) is a heavy-duty industrial switching device engineered for precise & reliable control of medium to high-capacity electric motors & inductive loads in demanding industrial environments. With a 50A current rating & a 3 pole configuration, it is ideally suited for higher-capacity motor control applications requiring durability, stability, & long operational life.
Designed for AC 3 duty applications, this contactor effectively manages inductive loads such as motors, compressors, pumps, conveyors, & HVAC systems, handling high inrush currents during motor startup & ensuring stable switching during continuous operation. The MNX series is known for its rugged design, compact construction, & reliability, making it a preferred choice for industrial automation systems.
The 110V AC coil (50–60 Hz) ensures compatibility with standard control circuit voltages, allowing smooth & reliable integration into control panels. Built with premium-quality materials & precision engineering, this contactor offers consistent switching performance, enhanced durability, & dependable operation in harsh industrial conditions.
Purpose & Function
This contactor is designed for high-capacity motor control & industrial automation:
• Controls medium to large three-phase motors
• Handles high inrush current during motor startup
• Provides reliable switching & operational stability
• Supports industrial automation & process systems
• Enhances efficiency & performance of electrical installations
Electrical Configuration
• Product type: Contactor
• Model: MNX
• Rated current: 50A
• Number of poles: 3P
• Voltage rating: 415V AC
• Utilization category: AC 3 (motor loads)
• Coil voltage: 110V AC
• Frequency: 50–60 Hz
• Function: Motor switching, control, & protection
Construction & Design
Engineered for heavy-duty industrial performance:
• High-quality contacts for superior electrical conductivity
• Rugged & compact design for panel efficiency
• Durable construction ensures long service life
• Precision switching mechanism for consistent operation
• High mechanical & electrical endurance
Safety & Protection
• Ensures safe motor starting & stopping
• Handles higher electrical loads safely
• Reduces risk of electrical faults & equipment damage
• Provides stable switching under inductive load conditions
• Improves system safety & reliability
Mounting & Installation
• Suitable for panel or DIN rail mounting
• Compact structure for optimized panel space
• Easy & secure installation process
• Simplified wiring & integration
• Ensures stable & reliable electrical connections
Application Domains
• Motor control centers (MCC panels)
• Industrial automation systems
• Heavy-duty pumps & compressors
• Conveyor systems & production lines
• HVAC & process industries
• Electrical control panels
Key Features
• 50A rated MNX contactor
• 3-pole configuration for motor control
• AC 3 duty for inductive loads
• 110V AC coil (50–60 Hz)
• Heavy-duty, rugged, & industrial-grade design
Applications
• Medium to large motor switching & control
• Industrial automation systems
• Pump & compressor applications
• Conveyor & machinery operations
• Electrical control panels
FAQs
1. What is an AC 3 contactor?
Ans: An AC 3 contactor is designed for switching inductive loads such as motors & handling high starting currents safely.
2. What does 50A rating indicate?
Ans: It indicates the contactor can safely operate at up to 50 amps under normal conditions.
3. What is the advantage of a 110V coil?
Ans: It ensures compatibility with standard control voltages & stable operation in industrial panels.
4. Where is this contactor used?
Ans: It is used in industrial control panels, automation systems, & high-capacity motor applications.
5. Is it suitable for heavy-duty motors?
Ans: Yes, it is suitable for medium to high-capacity motor control applications.
6. What is MNX series known for?
Ans: The MNX series is known for durability, compact design, & reliable industrial performance.
7. Is installation easy?
Ans: Yes, it is designed for fast & secure installation in control panels.
Overview
| Ambient temperature | -20 to 55 degree C |
|---|---|
| Mechanical Life (No. of operating cycles) | 3600 Cy/Hr |
| Rated impulse withstand voltage (Uimp) | 8kV |
| Rated Insulation Voltage Ui (V) | 690V |
| Conformance to Standards | IS/IEC 6094741, IEC 6094741 |
| Coil Voltage | 110 V AC |
| Rated operational current at 415V | 50A |
| Discount Percentage | Between 0-10 % |
| No. of Poles | 3P |
| Height(mm) | 109 |
| Width(mm) | 89 |
| Depth(mm) | 120.5 |
| Rated kW | 26kW |
| Rated making capacity | 900V |
| Coil Operating band %Uc (Pick up) | 80 - 110 % |
| Rated breaking capacity | 750V |
| Mechanical Life | 10 Million |
| Coil Operating band %Uc (Drop off) | 35 - 65 % |
| Pick up VA consumption | 190VA |
| Hold on VA consumption | 21VA |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Lauritz Knudsen MNX Contactor 50A 3P 415V AC (AC 3) with 110V AC Coil (50–60 Hz) is a heavy-duty industrial switching device engineered for precise & reliable control of medium to high-capacity electric motors & inductive loads in demanding industrial environments. With a 50A current rating & a 3 pole configuration, it is ideally suited for higher-capacity motor control applications requiring durability, stability, & long operational life.
Designed for AC 3 duty applications, this contactor effectively manages inductive loads such as motors, compressors, pumps, conveyors, & HVAC systems, handling high inrush currents during motor startup & ensuring stable switching during continuous operation. The MNX series is known for its rugged design, compact construction, & reliability, making it a preferred choice for industrial automation systems.
The 110V AC coil (50–60 Hz) ensures compatibility with standard control circuit voltages, allowing smooth & reliable integration into control panels. Built with premium-quality materials & precision engineering, this contactor offers consistent switching performance, enhanced durability, & dependable operation in harsh industrial conditions.
Purpose & Function
This contactor is designed for high-capacity motor control & industrial automation:
• Controls medium to large three-phase motors
• Handles high inrush current during motor startup
• Provides reliable switching & operational stability
• Supports industrial automation & process systems
• Enhances efficiency & performance of electrical installations
Electrical Configuration
• Product type: Contactor
• Model: MNX
• Rated current: 50A
• Number of poles: 3P
• Voltage rating: 415V AC
• Utilization category: AC 3 (motor loads)
• Coil voltage: 110V AC
• Frequency: 50–60 Hz
• Function: Motor switching, control, & protection
Construction & Design
Engineered for heavy-duty industrial performance:
• High-quality contacts for superior electrical conductivity
• Rugged & compact design for panel efficiency
• Durable construction ensures long service life
• Precision switching mechanism for consistent operation
• High mechanical & electrical endurance
Safety & Protection
• Ensures safe motor starting & stopping
• Handles higher electrical loads safely
• Reduces risk of electrical faults & equipment damage
• Provides stable switching under inductive load conditions
• Improves system safety & reliability
Mounting & Installation
• Suitable for panel or DIN rail mounting
• Compact structure for optimized panel space
• Easy & secure installation process
• Simplified wiring & integration
• Ensures stable & reliable electrical connections
Application Domains
• Motor control centers (MCC panels)
• Industrial automation systems
• Heavy-duty pumps & compressors
• Conveyor systems & production lines
• HVAC & process industries
• Electrical control panels
Key Features
• 50A rated MNX contactor
• 3-pole configuration for motor control
• AC 3 duty for inductive loads
• 110V AC coil (50–60 Hz)
• Heavy-duty, rugged, & industrial-grade design
Applications
• Medium to large motor switching & control
• Industrial automation systems
• Pump & compressor applications
• Conveyor & machinery operations
• Electrical control panels
FAQs
1. What is an AC 3 contactor?
Ans: An AC 3 contactor is designed for switching inductive loads such as motors & handling high starting currents safely.
2. What does 50A rating indicate?
Ans: It indicates the contactor can safely operate at up to 50 amps under normal conditions.
3. What is the advantage of a 110V coil?
Ans: It ensures compatibility with standard control voltages & stable operation in industrial panels.
4. Where is this contactor used?
Ans: It is used in industrial control panels, automation systems, & high-capacity motor applications.
5. Is it suitable for heavy-duty motors?
Ans: Yes, it is suitable for medium to high-capacity motor control applications.
6. What is MNX series known for?
Ans: The MNX series is known for durability, compact design, & reliable industrial performance.
7. Is installation easy?
Ans: Yes, it is designed for fast & secure installation in control panels.
Overview
| Ambient temperature | -20 to 55 degree C |
|---|---|
| Mechanical Life (No. of operating cycles) | 3600 Cy/Hr |
| Rated impulse withstand voltage (Uimp) | 8kV |
| Rated Insulation Voltage Ui (V) | 690V |
| Conformance to Standards | IS/IEC 6094741, IEC 6094741 |
| Coil Voltage | 110 V AC |
| Rated operational current at 415V | 50A |
| Discount Percentage | Between 0-10 % |
| No. of Poles | 3P |
| Height(mm) | 109 |
| Width(mm) | 89 |
| Depth(mm) | 120.5 |
| Rated kW | 26kW |
| Rated making capacity | 900V |
| Coil Operating band %Uc (Pick up) | 80 - 110 % |
| Rated breaking capacity | 750V |
| Mechanical Life | 10 Million |
| Coil Operating band %Uc (Drop off) | 35 - 65 % |
| Pick up VA consumption | 190VA |
| Hold on VA consumption | 21VA |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.