Lauritz Knudsen Tripper, ACCL, EB/DG 30A/15A | 1 Pole with Neutral | 230V AC | Power Saving | CE Marked
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen Tripper, ACCL, EB/DG 30A/15A | 1 Pole with Neutral | 230V AC | Power Saving | CE Marked
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Tripper ACCL EEB 30A/DG 15A 1P+N 230V AC is a high-capacity Air Conditioner Control & Protection Device (ACCL) engineered to provide reliable switching, efficient operation, & enhanced safety for air conditioning systems & other heavy-duty single-phase appliances. It integrates switching, isolation, & overload protection into one compact & durable unit.
With a 30A switching capacity & a 15A protection rating, this device is ideal for high-capacity air conditioners, refrigeration systems, & other heavy electrical loads. The 1P+N (Single Pole + Neutral) configuration ensures simultaneous disconnection of both phase & neutral conductors, providing complete circuit isolation for improved safety during operation & maintenance.
How the Mechanism Works
This ACCL device combines control & protection features:
• Enables manual ON/OFF switching of connected appliances
• Provides overload protection to prevent equipment damage
• Disconnects both phase & neutral simultaneously
• Ensures safe isolation during maintenance or servicing
• Maintains stable & reliable operation of electrical loads
Technical Specifications
• Rated current (switching): 30A
• Protection rating: 15A
• Poles: 1P+N (Single Phase + Neutral)
• Rated voltage: 230V AC
• Function: Appliance control & overload protection
• Application: Air conditioners & similar high-load equipment
Construction & Design
The device is built for durability & high performance:
• Compact modular construction
• 1P+N configuration for complete circuit isolation
• DIN rail mountable for easy installation
• Smooth & robust switching mechanism
• High-quality internal components for long service life
Safety & Protection
• Provides overload protection for high-load appliances
• Ensures simultaneous disconnection of phase & neutral
• Reduces risk of electrical faults & equipment damage
• Enhances safety during operation & maintenance
• Ideal for dedicated appliance circuits
Mounting & Durability
• DIN rail mountable for quick installation
• Suitable for distribution boards & control panels
• Compact design for efficient panel layout
• Designed for long mechanical & electrical life
• Reliable under continuous heavy-load operation
Application Areas
• High-capacity air conditioning systems
• Refrigeration & cooling equipment
• Residential & commercial appliance circuits
• Dedicated equipment control panels
• Electrical distribution boards
Key Features
• 30A switching capacity
• 15A overload protection rating
• 1P+N configuration for full isolation
• Ideal for high-load AC & appliance protection
• Compact DIN rail mountable design
• Durable & heavy-duty construction
Applications
• High-capacity air conditioner circuits
• Refrigeration systems
• Heavy appliance protection & control
• Residential & commercial installations
• Equipment control panels
FAQs
1. What is an ACCL device?
Ans: ACCL (Air Conditioner Control andProtection Device) is designed to control & protect air conditioning units & similar appliances.
2. What does 1P+N mean?
Ans: 1P+N means the device disconnects both phase & neutral simultaneously for complete circuit isolation.
3. What does 15A protection rating indicate?
Ans: It indicates the rated overload protection current, helping protect high-load equipment from overcurrent damage.
4. Is this device suitable for air conditioners?
Ans: Yes, it is specifically designed for air conditioners & similar high-load appliances.
5. Does it provide overload protection?
Ans: Yes, it provides overload protection along with switching functionality.
6. Where is this device installed?
Ans: It is installed on a DIN rail inside a distribution board or control panel.
7. Why is neutral disconnection important?
Ans: Neutral disconnection ensures complete circuit isolation, improving safety during maintenance & fault conditions.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +50°C |
| Electrical life (Operating Cylces) | 6000 |
| Tightening Torque | 1.1Nm |
| Termination capacity | 10 Sq. mm (Rigid) 6 Sq. mm (Flexible) |
| No. of Poles | 1P+N |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Impulse Voltage | 2.5kV |
| Rated Conditional SC Current | 3kA |
| Current Rating | EB 30A/DG 15A |
| Rated operational voltage (Ue) | 230V |
| Conformance to Standards | IEC 60947-6, IEC 60947-3 |
| Length(mm) | 65.4 |
| Height(mm) | 90.5 |
| Breadth(mm) | 72 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Tripper ACCL EEB 30A/DG 15A 1P+N 230V AC is a high-capacity Air Conditioner Control & Protection Device (ACCL) engineered to provide reliable switching, efficient operation, & enhanced safety for air conditioning systems & other heavy-duty single-phase appliances. It integrates switching, isolation, & overload protection into one compact & durable unit.
With a 30A switching capacity & a 15A protection rating, this device is ideal for high-capacity air conditioners, refrigeration systems, & other heavy electrical loads. The 1P+N (Single Pole + Neutral) configuration ensures simultaneous disconnection of both phase & neutral conductors, providing complete circuit isolation for improved safety during operation & maintenance.
How the Mechanism Works
This ACCL device combines control & protection features:
• Enables manual ON/OFF switching of connected appliances
• Provides overload protection to prevent equipment damage
• Disconnects both phase & neutral simultaneously
• Ensures safe isolation during maintenance or servicing
• Maintains stable & reliable operation of electrical loads
Technical Specifications
• Rated current (switching): 30A
• Protection rating: 15A
• Poles: 1P+N (Single Phase + Neutral)
• Rated voltage: 230V AC
• Function: Appliance control & overload protection
• Application: Air conditioners & similar high-load equipment
Construction & Design
The device is built for durability & high performance:
• Compact modular construction
• 1P+N configuration for complete circuit isolation
• DIN rail mountable for easy installation
• Smooth & robust switching mechanism
• High-quality internal components for long service life
Safety & Protection
• Provides overload protection for high-load appliances
• Ensures simultaneous disconnection of phase & neutral
• Reduces risk of electrical faults & equipment damage
• Enhances safety during operation & maintenance
• Ideal for dedicated appliance circuits
Mounting & Durability
• DIN rail mountable for quick installation
• Suitable for distribution boards & control panels
• Compact design for efficient panel layout
• Designed for long mechanical & electrical life
• Reliable under continuous heavy-load operation
Application Areas
• High-capacity air conditioning systems
• Refrigeration & cooling equipment
• Residential & commercial appliance circuits
• Dedicated equipment control panels
• Electrical distribution boards
Key Features
• 30A switching capacity
• 15A overload protection rating
• 1P+N configuration for full isolation
• Ideal for high-load AC & appliance protection
• Compact DIN rail mountable design
• Durable & heavy-duty construction
Applications
• High-capacity air conditioner circuits
• Refrigeration systems
• Heavy appliance protection & control
• Residential & commercial installations
• Equipment control panels
FAQs
1. What is an ACCL device?
Ans: ACCL (Air Conditioner Control andProtection Device) is designed to control & protect air conditioning units & similar appliances.
2. What does 1P+N mean?
Ans: 1P+N means the device disconnects both phase & neutral simultaneously for complete circuit isolation.
3. What does 15A protection rating indicate?
Ans: It indicates the rated overload protection current, helping protect high-load equipment from overcurrent damage.
4. Is this device suitable for air conditioners?
Ans: Yes, it is specifically designed for air conditioners & similar high-load appliances.
5. Does it provide overload protection?
Ans: Yes, it provides overload protection along with switching functionality.
6. Where is this device installed?
Ans: It is installed on a DIN rail inside a distribution board or control panel.
7. Why is neutral disconnection important?
Ans: Neutral disconnection ensures complete circuit isolation, improving safety during maintenance & fault conditions.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -5°C to +50°C |
| Electrical life (Operating Cylces) | 6000 |
| Tightening Torque | 1.1Nm |
| Termination capacity | 10 Sq. mm (Rigid) 6 Sq. mm (Flexible) |
| No. of Poles | 1P+N |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Impulse Voltage | 2.5kV |
| Rated Conditional SC Current | 3kA |
| Current Rating | EB 30A/DG 15A |
| Rated operational voltage (Ue) | 230V |
| Conformance to Standards | IEC 60947-6, IEC 60947-3 |
| Length(mm) | 65.4 |
| Height(mm) | 90.5 |
| Breadth(mm) | 72 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.