Lauritz Knudsen Tripper, MCB, C-Curve, 6A | 2 Pole | Energy Saving | Higher Life | 240V AC
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen Tripper, MCB, C-Curve, 6A | 2 Pole | Energy Saving | Higher Life | 240V AC
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The Tripper MCB 6A DP 240V AC 6kA C Curve is a compact & reliable Miniature Circuit Breaker designed to provide effective protection against overload & short circuit faults in electrical circuits. It is ideal for residential & light commercial applications where low current loads & moderate inrush currents are present.
With a 6A current rating & 6kA breaking capacity, this MCB ensures safe interruption of fault currents. The double pole (DP) configuration provides simultaneous protection & disconnection of both phase & neutral conductors, enhancing safety. The C Curve characteristic makes it suitable for small inductive loads such as fans, small motors, & lighting with drivers.
How the Mechanism Works
This MCB ensures reliable circuit protection through automatic operation:
• Continuously monitors current flow in the circuit
• Trips during overload conditions exceeding safe limits
• Instantly disconnects supply during short circuit faults
• Allows moderate inrush currents without nuisance tripping
• Isolates both phase & neutral simultaneously
This ensures safe & stable operation of electrical systems.
Technical Specifications
• Rated current: 6A
• Poles: Double pole (DP)
• Rated voltage: 240V AC
• Breaking capacity: 6kA
• Tripping curve: C Curve
• Function: Overload & short circuit protection
• Application: Low load circuits with inductive loads
Construction & Design
The MCB is designed for durability & performance:
• Double pole design for full circuit isolation
• Compact modular DIN rail mountable structure
• C Curve tripping suitable for moderate inrush current circuits
• Efficient arc extinguishing mechanism
• High-quality internal components for reliability
Safety & Protection
• Protects against overload & short circuit faults
• Ensures complete isolation of phase & neutral
• Prevents damage to wiring & connected devices
• Suitable for circuits with moderate surge currents
• Enhances system safety & operational reliability
Mounting & Durability
• DIN rail mountable for quick installation
• Suitable for distribution boards & panels
• Compact modular construction for efficient space usage
• Designed for long mechanical & electrical life
• Reliable under regular & continuous operation
Application Areas
• Residential electrical systems
• Fan & small motor circuits
• Lighting with drivers & inductive loads
• Commercial low-load installations
• Distribution boards
Key Features
• 6A rated MCB for low load applications
• Double pole (DP) configuration
• 6kA breaking capacity
• C Curve for moderate inrush current circuits
• Full phase & neutral isolation
• Compact DIN rail mountable design
• Durable & reliable construction
Applications
• Fan & small motor circuits
• Residential wiring systems
• Lighting circuits with drivers
• Low-load commercial panels
• Electrical distribution boards
FAQs
1. What does DP mean in this MCB?
Ans: DP (Double Pole) means it disconnects both phase & neutral simultaneously for complete isolation.
2. What does C Curve indicate?
Ans: C Curve is suitable for circuits with moderate inrush currents such as inductive loads & small motors.
3. Where is a 6A DP MCB used?
Ans: It is used in low load circuits such as fans, lighting, & small appliances requiring full isolation.
4. What is the importance of 6kA breaking capacity?
Ans: It ensures safe interruption of fault currents up to 6kA.
5. Does it protect against short circuits?
Ans: Yes, it provides protection against both overload & short circuit conditions.
6. How is this MCB installed?
Ans: It is installed on a DIN rail inside a distribution board.
7. Why use a DP MCB instead of SP?
Ans: DP MCB provides complete isolation by disconnecting both phase & neutral, improving safety during maintenance & faults.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +70°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 6kA |
| Rated Impulse Voltage | 4kV |
| Current Rating | 6A |
| Rated operational voltage (Ue) | 240V |
| Conformance to Standards | IS/IEC 60898-1 |
| Tripping Characteristic | C Curve |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Tripper MCB 6A DP 240V AC 6kA C Curve is a compact & reliable Miniature Circuit Breaker designed to provide effective protection against overload & short circuit faults in electrical circuits. It is ideal for residential & light commercial applications where low current loads & moderate inrush currents are present.
With a 6A current rating & 6kA breaking capacity, this MCB ensures safe interruption of fault currents. The double pole (DP) configuration provides simultaneous protection & disconnection of both phase & neutral conductors, enhancing safety. The C Curve characteristic makes it suitable for small inductive loads such as fans, small motors, & lighting with drivers.
How the Mechanism Works
This MCB ensures reliable circuit protection through automatic operation:
• Continuously monitors current flow in the circuit
• Trips during overload conditions exceeding safe limits
• Instantly disconnects supply during short circuit faults
• Allows moderate inrush currents without nuisance tripping
• Isolates both phase & neutral simultaneously
This ensures safe & stable operation of electrical systems.
Technical Specifications
• Rated current: 6A
• Poles: Double pole (DP)
• Rated voltage: 240V AC
• Breaking capacity: 6kA
• Tripping curve: C Curve
• Function: Overload & short circuit protection
• Application: Low load circuits with inductive loads
Construction & Design
The MCB is designed for durability & performance:
• Double pole design for full circuit isolation
• Compact modular DIN rail mountable structure
• C Curve tripping suitable for moderate inrush current circuits
• Efficient arc extinguishing mechanism
• High-quality internal components for reliability
Safety & Protection
• Protects against overload & short circuit faults
• Ensures complete isolation of phase & neutral
• Prevents damage to wiring & connected devices
• Suitable for circuits with moderate surge currents
• Enhances system safety & operational reliability
Mounting & Durability
• DIN rail mountable for quick installation
• Suitable for distribution boards & panels
• Compact modular construction for efficient space usage
• Designed for long mechanical & electrical life
• Reliable under regular & continuous operation
Application Areas
• Residential electrical systems
• Fan & small motor circuits
• Lighting with drivers & inductive loads
• Commercial low-load installations
• Distribution boards
Key Features
• 6A rated MCB for low load applications
• Double pole (DP) configuration
• 6kA breaking capacity
• C Curve for moderate inrush current circuits
• Full phase & neutral isolation
• Compact DIN rail mountable design
• Durable & reliable construction
Applications
• Fan & small motor circuits
• Residential wiring systems
• Lighting circuits with drivers
• Low-load commercial panels
• Electrical distribution boards
FAQs
1. What does DP mean in this MCB?
Ans: DP (Double Pole) means it disconnects both phase & neutral simultaneously for complete isolation.
2. What does C Curve indicate?
Ans: C Curve is suitable for circuits with moderate inrush currents such as inductive loads & small motors.
3. Where is a 6A DP MCB used?
Ans: It is used in low load circuits such as fans, lighting, & small appliances requiring full isolation.
4. What is the importance of 6kA breaking capacity?
Ans: It ensures safe interruption of fault currents up to 6kA.
5. Does it protect against short circuits?
Ans: Yes, it provides protection against both overload & short circuit conditions.
6. How is this MCB installed?
Ans: It is installed on a DIN rail inside a distribution board.
7. Why use a DP MCB instead of SP?
Ans: DP MCB provides complete isolation by disconnecting both phase & neutral, improving safety during maintenance & faults.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +70°C |
| Electrical life (Operating Cylces) | 10000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 100000 |
| No. of Poles | DP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 6kA |
| Rated Impulse Voltage | 4kV |
| Current Rating | 6A |
| Rated operational voltage (Ue) | 240V |
| Conformance to Standards | IS/IEC 60898-1 |
| Tripping Characteristic | C Curve |
| Length(mm) | 74.5 |
| Height(mm) | 87.3 |
| Breadth(mm) | 35 |
Documents
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.