Lauritz Knudsen AU HR MCB, 4 Pole, C Curve, 15kA, 100A, 415V | Suitable for Isolation | Protection Degree - IP 20
calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen AU HR MCB, 4 Pole, C Curve, 15kA, 100A, 415V | Suitable for Isolation | Protection Degree - IP 20
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The AU HR MCB 100A FP 415V AC 15kA C Curve is a high-capacity Miniature Circuit Breaker designed to protect three phase electrical systems against overloads & short circuits. It is ideal for industrial, commercial, & high-load applications requiring dependable protection & complete circuit isolation.
With a 100A current rating & a high breaking capacity of 15kA, this MCB ensures safe interruption of fault currents even under severe conditions. The four pole (FP) configuration provides protection & isolation for all three phases along with the neutral, ensuring comprehensive system safety.
How the MCB Works
This MCB provides automatic protection through continuous monitoring:
• Monitors current flow across all three phases & neutral
• Trips during sustained overload conditions
• Instantly disconnects supply during short circuit faults
• Simultaneously isolates all phases & neutral
This ensures safe operation & protection of electrical systems & connected equipment.
Electrical Configuration
• Rated current: 100A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Breaking capacity: 15kA
• Tripping curve: C Curve
• Function: Overload & short circuit protection
• Application: High-capacity three phase systems
Construction & Design
The MCB is engineered for durability & industrial-grade performance:
• Four pole design for complete system isolation
• High 15kA breaking capacity for heavy fault conditions
• C Curve tripping suitable for inductive & moderate inrush loads
• Compact modular design compatible with DIN rail mounting
• Advanced arc extinguishing mechanism
• Reliable & consistent tripping performance
Safety & Protection
• Protects against overload & short circuit faults
• Ensures simultaneous disconnection of all phases & neutral
• Reduces risk of equipment damage & electrical hazards
• Enhances system stability & operational safety
• Supports safe maintenance & fault handling
Mounting & Durability
• DIN rail mountable for easy installation
• Suitable for distribution boards & industrial control panels
• Compact modular construction
• Designed for long mechanical & electrical life
• Reliable under continuous & high-load operation
Application Domains
• Industrial electrical systems
• Commercial installations
• Three phase distribution boards
• Motor & machinery circuits
• HVAC & inductive load applications
Key Features
• 100A rated MCB for high load three phase applications
• Four pole (FP) configuration including neutral isolation
• 15kA high breaking capacity
• C Curve for inductive & moderate inrush loads
• Reliable overload & short circuit protection
• DIN rail mountable compact design
• Durable & long-lasting construction
Applications
• Industrial power distribution
• Commercial electrical systems
• Three phase distribution boards
• Motor & equipment protection
• High capacity power circuits
FAQs
1. What does FP mean in this MCB?
Ans: FP (Four Pole) means the breaker disconnects all three phases & the neutral simultaneously for complete isolation.
2. What is the significance of 15kA breaking capacity?
Ans: It ensures the MCB can safely interrupt high fault currents up to 15kA.
3. Why is a C Curve used?
Ans: C Curve is suitable for circuits with moderate inrush currents such as motors & inductive loads.
4. Where is a 100A FP MCB used?
Ans: It is used in high-capacity three phase systems in industrial & commercial applications.
5. Does it isolate the neutral conductor?
Ans: Yes, the four pole design ensures neutral isolation along with all three phases.
6. How is this MCB installed?
Ans: It is installed on a DIN rail inside a distribution board or control panel.
7. Why is an FP MCB important?
Ans: It provides complete circuit isolation, enhancing safety & ensuring reliable operation in three phase electrical systems.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60° C |
| Electrical life (Operating Cylces) | 5,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 70 Sq. mm (Rigid) 50 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 15kA |
| Rated Impulse Voltage | 6kV |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 60947-2 |
| Tripping Characteristic | C Curve |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 105.2 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The AU HR MCB 100A FP 415V AC 15kA C Curve is a high-capacity Miniature Circuit Breaker designed to protect three phase electrical systems against overloads & short circuits. It is ideal for industrial, commercial, & high-load applications requiring dependable protection & complete circuit isolation.
With a 100A current rating & a high breaking capacity of 15kA, this MCB ensures safe interruption of fault currents even under severe conditions. The four pole (FP) configuration provides protection & isolation for all three phases along with the neutral, ensuring comprehensive system safety.
How the MCB Works
This MCB provides automatic protection through continuous monitoring:
• Monitors current flow across all three phases & neutral
• Trips during sustained overload conditions
• Instantly disconnects supply during short circuit faults
• Simultaneously isolates all phases & neutral
This ensures safe operation & protection of electrical systems & connected equipment.
Electrical Configuration
• Rated current: 100A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Breaking capacity: 15kA
• Tripping curve: C Curve
• Function: Overload & short circuit protection
• Application: High-capacity three phase systems
Construction & Design
The MCB is engineered for durability & industrial-grade performance:
• Four pole design for complete system isolation
• High 15kA breaking capacity for heavy fault conditions
• C Curve tripping suitable for inductive & moderate inrush loads
• Compact modular design compatible with DIN rail mounting
• Advanced arc extinguishing mechanism
• Reliable & consistent tripping performance
Safety & Protection
• Protects against overload & short circuit faults
• Ensures simultaneous disconnection of all phases & neutral
• Reduces risk of equipment damage & electrical hazards
• Enhances system stability & operational safety
• Supports safe maintenance & fault handling
Mounting & Durability
• DIN rail mountable for easy installation
• Suitable for distribution boards & industrial control panels
• Compact modular construction
• Designed for long mechanical & electrical life
• Reliable under continuous & high-load operation
Application Domains
• Industrial electrical systems
• Commercial installations
• Three phase distribution boards
• Motor & machinery circuits
• HVAC & inductive load applications
Key Features
• 100A rated MCB for high load three phase applications
• Four pole (FP) configuration including neutral isolation
• 15kA high breaking capacity
• C Curve for inductive & moderate inrush loads
• Reliable overload & short circuit protection
• DIN rail mountable compact design
• Durable & long-lasting construction
Applications
• Industrial power distribution
• Commercial electrical systems
• Three phase distribution boards
• Motor & equipment protection
• High capacity power circuits
FAQs
1. What does FP mean in this MCB?
Ans: FP (Four Pole) means the breaker disconnects all three phases & the neutral simultaneously for complete isolation.
2. What is the significance of 15kA breaking capacity?
Ans: It ensures the MCB can safely interrupt high fault currents up to 15kA.
3. Why is a C Curve used?
Ans: C Curve is suitable for circuits with moderate inrush currents such as motors & inductive loads.
4. Where is a 100A FP MCB used?
Ans: It is used in high-capacity three phase systems in industrial & commercial applications.
5. Does it isolate the neutral conductor?
Ans: Yes, the four pole design ensures neutral isolation along with all three phases.
6. How is this MCB installed?
Ans: It is installed on a DIN rail inside a distribution board or control panel.
7. Why is an FP MCB important?
Ans: It provides complete circuit isolation, enhancing safety & ensuring reliable operation in three phase electrical systems.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60° C |
| Electrical life (Operating Cylces) | 5,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 70 Sq. mm (Rigid) 50 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz/60Hz |
| Rated Short-circuit Breaking Capacity | 15kA |
| Rated Impulse Voltage | 6kV |
| Current Rating | 100A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 60947-2 |
| Tripping Characteristic | C Curve |
| Length(mm) | 77.5 |
| Height(mm) | 100.6 |
| Breadth(mm) | 105.2 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.