Lauritz Knudsen AU Standard RCBO, 4 Pole, C Curve, 10 kA, 30 mA, 16A, 415V | Suitable for Isolation| with Enhanced Safety
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen AU Standard RCBO, 4 Pole, C Curve, 10 kA, 30 mA, 16A, 415V | Suitable for Isolation| with Enhanced Safety
- Description
- Specifications
- Documents
- Warranty
- Reviews
Description
About the Product
The AU RCBO 16A FP 415V AC 10kA 30mA C Curve is a four pole residual current breaker with overload protection that integrates both MCB & RCCB functionalities in a single unit. It is specifically designed for three phase systems requiring comprehensive circuit protection.
With a 16A current rating, this RCBO is suitable for medium load three phase circuits. The 30mA leakage sensitivity ensures effective protection against electric shock, making it ideal for safety-focused commercial & industrial installations.
How the RCBO Works
This four pole RCBO operates as a combined protection system:
• Detects overload & short circuit conditions similar to an MCB
• Detects earth leakage currents like an RCCB
• Trips automatically when fault conditions are detected
• Disconnects all three phases & neutral simultaneously
This ensures complete isolation of the circuit & enhanced protection in three phase systems.
Electrical Configuration
• Rated current: 16A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Breaking capacity: 10kA
• Sensitivity: 30mA
• Trip curve: C Curve
• Application: Overload, short circuit, & earth leakage protection
Construction & Design
The RCBO is designed for reliable three phase operation:
• Integrated MCB & RCCB functionality in one device
• Modular design suitable for DIN rail mounting
• Compact construction for efficient use of panel space
• High mechanical & electrical endurance
• Designed for accurate & consistent tripping performance
Safety & Protection
• Protects against overload & short circuit faults
• 30mA sensitivity provides protection against electric shock
• Detects & isolates earth leakage currents
• Four pole disconnection ensures complete system isolation
• Reduces risk of electrical hazards, fire, & equipment damage
Mounting & Durability
• DIN rail mounting for easy installation in distribution boards• Suitable for three phase panels & control systems
• Compact modular construction
• Designed for frequent operation & fault handling
• Built for long term durability & stable performance
Application Domains
• Three phase distribution boards
• Industrial electrical installations
• Commercial buildings
• Control panels & machinery circuits
• Equipment requiring three phase protection
Key Features
• 16A rated RCBO for three phase medium load circuits
• Four pole design for complete phase & neutral isolation
• 10kA breaking capacity for reliable fault interruption
• 30mA sensitivity for personnel safety
• C curve characteristic for general purpose applications
• Combines MCB & RCCB functions in one unit
• DIN rail compatible for easy installation
Applications
• Industrial panels
• Commercial three phase systems
• Machinery & equipment circuits
• Distribution boards
• Electrical control systems
FAQs
1. What does FP mean in this RCBO?
Ans: FP stands for four pole, meaning it controls & isolates three phases & one neutral simultaneously.
2. What is the voltage rating of this RCBO?
Ans: It is designed for 415V AC three phase systems.
3. What does 30mA sensitivity indicate?
Ans: It provides protection against electric shock by detecting low leakage currents.
4. Why is a four pole RCBO used?
Ans: It ensures complete disconnection of all phases & neutral in three phase circuits.
5. What is the breaking capacity of this device?
Ans: It has a breaking capacity of 10kA, meaning it can safely handle high fault currents.
6. What is a C curve characteristic?
Ans: It is suitable for general purpose circuits with moderate inrush currents such as motors & equipment.
7. Where can this RCBO be used?
Ans: It is used in industrial & commercial three phase installations requiring combined electrical protection.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Short-circuit Breaking Capacity | 10kA as per IEC 61009-1 |
| Rated Impulse Voltage | 6kV |
| Current Rating | 16A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61009-1, IS 12640-2 |
| Tripping Characteristic | C Curve |
| Sensitivity | 30mA |
| Length(mm) | 77.5 |
| Height(mm) | 103.8 |
| Breadth(mm) | 131.25 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The AU RCBO 16A FP 415V AC 10kA 30mA C Curve is a four pole residual current breaker with overload protection that integrates both MCB & RCCB functionalities in a single unit. It is specifically designed for three phase systems requiring comprehensive circuit protection.
With a 16A current rating, this RCBO is suitable for medium load three phase circuits. The 30mA leakage sensitivity ensures effective protection against electric shock, making it ideal for safety-focused commercial & industrial installations.
How the RCBO Works
This four pole RCBO operates as a combined protection system:
• Detects overload & short circuit conditions similar to an MCB
• Detects earth leakage currents like an RCCB
• Trips automatically when fault conditions are detected
• Disconnects all three phases & neutral simultaneously
This ensures complete isolation of the circuit & enhanced protection in three phase systems.
Electrical Configuration
• Rated current: 16A
• Poles: Four pole (FP – 3 phase + neutral)
• Rated voltage: 415V AC
• Breaking capacity: 10kA
• Sensitivity: 30mA
• Trip curve: C Curve
• Application: Overload, short circuit, & earth leakage protection
Construction & Design
The RCBO is designed for reliable three phase operation:
• Integrated MCB & RCCB functionality in one device
• Modular design suitable for DIN rail mounting
• Compact construction for efficient use of panel space
• High mechanical & electrical endurance
• Designed for accurate & consistent tripping performance
Safety & Protection
• Protects against overload & short circuit faults
• 30mA sensitivity provides protection against electric shock
• Detects & isolates earth leakage currents
• Four pole disconnection ensures complete system isolation
• Reduces risk of electrical hazards, fire, & equipment damage
Mounting & Durability
• DIN rail mounting for easy installation in distribution boards• Suitable for three phase panels & control systems
• Compact modular construction
• Designed for frequent operation & fault handling
• Built for long term durability & stable performance
Application Domains
• Three phase distribution boards
• Industrial electrical installations
• Commercial buildings
• Control panels & machinery circuits
• Equipment requiring three phase protection
Key Features
• 16A rated RCBO for three phase medium load circuits
• Four pole design for complete phase & neutral isolation
• 10kA breaking capacity for reliable fault interruption
• 30mA sensitivity for personnel safety
• C curve characteristic for general purpose applications
• Combines MCB & RCCB functions in one unit
• DIN rail compatible for easy installation
Applications
• Industrial panels
• Commercial three phase systems
• Machinery & equipment circuits
• Distribution boards
• Electrical control systems
FAQs
1. What does FP mean in this RCBO?
Ans: FP stands for four pole, meaning it controls & isolates three phases & one neutral simultaneously.
2. What is the voltage rating of this RCBO?
Ans: It is designed for 415V AC three phase systems.
3. What does 30mA sensitivity indicate?
Ans: It provides protection against electric shock by detecting low leakage currents.
4. Why is a four pole RCBO used?
Ans: It ensures complete disconnection of all phases & neutral in three phase circuits.
5. What is the breaking capacity of this device?
Ans: It has a breaking capacity of 10kA, meaning it can safely handle high fault currents.
6. What is a C curve characteristic?
Ans: It is suitable for general purpose circuits with moderate inrush currents such as motors & equipment.
7. Where can this RCBO be used?
Ans: It is used in industrial & commercial three phase installations requiring combined electrical protection.
Overview
| Discount Percentage | Between 0-10 % |
|---|---|
| Operating Temperature Range | -25°C to +60°C |
| Electrical life (Operating Cylces) | 10,000 |
| Tightening Torque | 4Nm |
| Termination capacity | 35 Sq. mm (Rigid) 25 Sq. mm (Flexible) |
| Mechanical Life (Operating Cycles) | 20,000 |
| No. of Poles | FP |
| Rated Insulation Voltage Ui (V) | 500V |
| Rated Frequency | 50Hz |
| Rated Short-circuit Breaking Capacity | 10kA as per IEC 61009-1 |
| Rated Impulse Voltage | 6kV |
| Current Rating | 16A |
| Rated operational voltage (Ue) | 415V |
| Conformance to Standards | IEC 61009-1, IS 12640-2 |
| Tripping Characteristic | C Curve |
| Sensitivity | 30mA |
| Length(mm) | 77.5 |
| Height(mm) | 103.8 |
| Breadth(mm) | 131.25 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.