Lauritz Knudsen EXORA, Distribution Board (DB) VTPN, Double Door, IP43 MCCB I/C, 125A, 12 Way
calcPageSize())"
/>
Further offers for this product
Incl. Tax
In Stock
No sellers found for this product.
Incl. Tax
Lauritz Knudsen EXORA, Distribution Board (DB) VTPN, Double Door, IP43 MCCB I/C, 125A, 12 Way
- Description
- Specifications
- Warranty
- Reviews
Description
About the Product
The Exora DB VTPN 12 Way Double Door IP43 distribution board with 125A MCCB incomer is a vertical three phase and neutral enclosure designed to support up to 12 outgoing circuits for modular protection devices such as MCBs, RCCBs, and isolators.
It is designed with provision for a 125A MCCB incomer, ensuring reliable protection against overload and short circuit faults. The double door construction combined with IP43 protection enhances operational safety and durability in semi protected environments.
How the Distribution Board Works
This VTPN distribution board operates as a structured three phase electrical system:
- The 125A MCCB incomer acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases and neutral
- Outgoing circuits are controlled through modular protection devices
- Ensures safe, organized, and balanced load distribution across phases
The MCCB enables centralized protection and improves overall system reliability.
Electrical Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 12 way
- Incomer: MCCB up to 125A
- Outgoing configuration: 12 + 12 + 12 modules
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal setup:
- Insulated busbar system for three phase distribution
- Neutral and earth bars with protection
- DIN rail mounting system for modular devices
- Adequate space for wiring and cable management
- Circuit identification and labeling provision
It is designed as a ready to install enclosure ensuring organized wiring and easy installation.
Safety and Protection
- MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with live electrical parts
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Robust metal construction with protective coating
- Suitable for commercial and industrial environments
- Built for long term durability
Application Domains
- Commercial electrical distribution systems
- Industrial installations and manufacturing units
- Three phase residential setups
- Control and distribution panels
- Medium to high capacity sub distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 12 way circuit capacity for multiple outgoing connections
- Supports MCCB incomer up to 125A
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible system for modular device installation
- Pre configured busbar, neutral and earth system
Applications
- Commercial buildings
- Industrial facilities
- Electrical control panels
- Machinery and equipment distribution
- Three phase load management systems
FAQs
1. What is the function of the MCCB in this distribution board?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions and enabling safe isolation.
2. What does VTPN mean?
Ans: VTPN stands for Vertical Three Phase and Neutral, used for distributing three phase electrical power.
3. What does 12 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
4. Is the MCCB included in the distribution board?
Ans: The enclosure is designed for a 125A MCCB incomer, which is typically supplied separately.
5. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
6. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
7. Can it be used outdoors?
Ans: It is suitable for indoor or covered installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 12 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 125A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 16+16+16 |
| Height(mm) | 753 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.
Reviews
Description
About the Product
The Exora DB VTPN 12 Way Double Door IP43 distribution board with 125A MCCB incomer is a vertical three phase and neutral enclosure designed to support up to 12 outgoing circuits for modular protection devices such as MCBs, RCCBs, and isolators.
It is designed with provision for a 125A MCCB incomer, ensuring reliable protection against overload and short circuit faults. The double door construction combined with IP43 protection enhances operational safety and durability in semi protected environments.
How the Distribution Board Works
This VTPN distribution board operates as a structured three phase electrical system:
- The 125A MCCB incomer acts as the main protection and isolation device
- Incoming electrical supply is distributed across R, Y, B phases and neutral
- Outgoing circuits are controlled through modular protection devices
- Ensures safe, organized, and balanced load distribution across phases
The MCCB enables centralized protection and improves overall system reliability.
Electrical Configuration
- System type: VTPN (Vertical Three Phase and Neutral)
- Way / capacity: 12 way
- Incomer: MCCB up to 125A
- Outgoing configuration: 12 + 12 + 12 modules
- Rated voltage: 240/415V AC
- Standards compliance: IS and IEC standards for distribution boards
Construction and Internal Configuration
The distribution board includes a structured internal setup:
- Insulated busbar system for three phase distribution
- Neutral and earth bars with protection
- DIN rail mounting system for modular devices
- Adequate space for wiring and cable management
- Circuit identification and labeling provision
It is designed as a ready to install enclosure ensuring organized wiring and easy installation.
Safety and Protection
- MCCB incomer provides overload and short circuit protection
- IP43 protection against dust and water splashes
- Double door enclosure ensures enhanced safety and controlled access
- Prevents accidental contact with live electrical parts
- Organized internal layout improves safety and reduces wiring errors
Mounting and Durability
- Designed for wall or surface mounting
- Compact vertical enclosure for efficient space utilization
- Robust metal construction with protective coating
- Suitable for commercial and industrial environments
- Built for long term durability
Application Domains
- Commercial electrical distribution systems
- Industrial installations and manufacturing units
- Three phase residential setups
- Control and distribution panels
- Medium to high capacity sub distribution boards
Key Features
- VTPN configuration for three phase and neutral distribution
- 12 way circuit capacity for multiple outgoing connections
- Supports MCCB incomer up to 125A
- Double door design for improved safety and access control
- IP43 protection for dust and water splash resistance
- DIN rail compatible system for modular device installation
- Pre configured busbar, neutral and earth system
Applications
- Commercial buildings
- Industrial facilities
- Electrical control panels
- Machinery and equipment distribution
- Three phase load management systems
FAQs
1. What is the function of the MCCB in this distribution board?
Ans: The MCCB acts as the main incomer, providing protection against overload and short circuit conditions and enabling safe isolation.
2. What does VTPN mean?
Ans: VTPN stands for Vertical Three Phase and Neutral, used for distributing three phase electrical power.
3. What does 12 way mean?
Ans: It refers to the number of outgoing circuits supported by the distribution board.
4. Is the MCCB included in the distribution board?
Ans: The enclosure is designed for a 125A MCCB incomer, which is typically supplied separately.
5. What is the advantage of a double door enclosure?
Ans: It provides enhanced safety, controlled access, and better protection of internal components.
6. What does IP43 protection mean?
Ans: It ensures protection against solid particles and water splashes in semi protected environments.
7. Can it be used outdoors?
Ans: It is suitable for indoor or covered installations but not for fully exposed outdoor environments.
Overview
| Door Type | Double Door IP43 |
|---|---|
| No of Ways | 12 |
| Discount Percentage | Between 0-10 % |
| Conformance to standards | IS 8623-1 & 3 IEC 61439-1 & 3 |
| No of Module Incomer | 125A MCCB |
| Protection against Mechanical Impact | IK 09 |
| No of Module Outgoing | 16+16+16 |
| Height(mm) | 753 |
| Breadth(mm) | 487 |
| Depth(mm) | 108 |
Warranty
- All products listed in the price list are covered by a warranty against manufacturing defects for a period of 18* months from the date of purchase.
- For Lauritz Knudsen MCBs & Isolators mounted inside Lauritz Knudsen Distribution Boards, an extended warranty of 5 years is provided.
- In the event of a defect due to faulty workmanship or other associated reasons, the manufacturer will, at its discretion, remedy the defect or replace the faulty parts or the entire product as soon as possible, free of cost.
- This warranty is subject to proper usage and efficient maintenance and does not cover defects arising from fire, accidents, inefficient maintenance, faulty operation, or deliberate or accidental damage.
- The warranty does not cover damage to power electronic components such as thyristors & IGBTs, which primarily fail due to over-temperature or over-voltage. Users must take adequate precautions to eliminate such conditions.
- The manufacturer shall not be responsible or liable for any special, incidental, social, or consequential losses (including loss of profits), punitive damages, injury, or damages of any kind solely attributable to defect or failure of its products.
- The manufacturer shall not be liable in any manner for issues related to or failure in the performance of any other equipment to which the product is connected.